4.6.1.1 RS-449 / DC-37 Interface

This interface complies with EIA Standard RS-449. Electrical characteristics comply
with RS-422 for clock and data signals and RS-423 for control signals. The interface
uses the physical connector type and pinouts specified in RS-449 (refer to Table 4-H).
The RS-449 / 422 interface uses a 37-pin, female D-Type connector for the physical
connection.

Table 4-H.

RS-449 Pinouts
for Model MC1

Pin

RS-449

Direction

Number

Pin Name

A/B

(abbrev)

(full name)

1

SHLD

shield

-

4/22

SD

send data

to modem

5/23

ST

send timing

from modem

6/24

RD

receive data

from modem

7/25

RS

request to send

to modem

8/26

RT

receive timing

from modem

9/27

CS

clear to send

from modem

10

LL

local loopback

to modem

11/29

DM

data mode

from modem

12/30

TR

terminal ready

to modem

13/31

RR

receiver ready

from modem

14

RL

remote loopback

to modem

15

IC

incoming call

from modem

17/35

TT

terminal timing

to modem

18

TM

test mode

from modem

19

SG

signal ground

-

20

RC

receive common

-

37

SC

send common

to modem

2/36

N/A

extra clock for

to modem

receive data