CANOGA PERKINS OADM User Manual

Installation guide oadm

Advertising
background image

Installation Guide

OADM

Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com

P/N 6912425 Rev C

Overview
This document provides steps necessary to correctly install and configure
Canoga Perkins’ passive OADM product. The passive OADM comes in two
configurations: “Drop and Continue” and “Drop and Insert.”

Installation
Ensure that there is no visible damage to the OADM module and that the OADM
module meets the installation requirements. Refer to the Technical Specifications
page. The OADM can be installed in either slot of a UCS 1001 or in a UCS 1000.
Insert the OADM module in either slot of a UCS 1001 Chassis. Insert the 6702 in
the other slot. See figure 1.

Figure 1

Drop and continue applications
Items required

1 x Model number OADM-2001-xx03

1 x Model number 6702 (Remote wavelength must match the OADM’s

dropped wavelength)

1 x UCS 1001 or UCS 1000

Singlemode fiber optic jumpers

Identify the West Link Tx/Rx fiber pair and East Link Tx/Rx fiber pair.

The West Link Tx/Rx fiber pair is the composite optical signal to and from

the central location or West location.

The East Link Tx/Rx fiber pair is the optical signal continuing to and coming

from the East site.

Connect the OADM to the link. See Figure 2.