Figure 4. p53 interface for external function – CANOGA PERKINS 2340 Universal Fiber Optic Modem User Manual

Page 18

Advertising
background image

Model 2340 Model User Manual

3-4

Use the Internal configuration when the network equipment is set for Internal Timing (see Figure 3).
In this application, the modems act as the network timing source. When connecting KG or KIV
encryptors on the Black side, go to the Functional Configuration screen and set the interface
configuration parameters: set the operating mode to Internal, then set the Internal Rate, then set the
delay time; for details, see Section 4.7.

FIFO

RX Data

RX Clock

Delay Line

Internal

Clock

TX Clock

TX Data

RXD

SCR

SCT

SCTE

TXD

J1, DB-25

Figure 3. P53 Interface for Internal Clock

Use the External configuration when the network equipment is set for Network or Internal Timing
(see Figure 4). In this application, the modems act as an extension of the Red side cable in a true tail
circuit. When connecting KG or KIV encryptors on the Red side to a DTE device, go to the
Functional Configuration screen and set the interface configuration parameters: set the operating
mode for the modem at the Red end to External and the modem at the DTE end to Slave; for details,
see Section 4.7.

FIFO

RX Data

RX Clock

Delay Line

Internal

Clock

TX Clock

TX Data

RXD

SCR

SCT

SCTE

TXD

J1, DB-25

Figure 4. P53 Interface for External Function

Advertising