13 interface status, 14 link error counters, Interface status -14 – CANOGA PERKINS 2370 High-Speed Universal Fiber Optic Modem User Manual

Page 42: Link error counters -14, Figure 18. interface status screen -14

Advertising
background image

4.13 Interface

Status

The Interface Status report provides information about the local and remote interface types, the
current data rate, and the controls for the interface type. See Figure 18. To view the 2370 interface
status, follow these steps:

1. From the Main Menu type 3, "Interface Status," and press <Enter>.

2. To return to the System Configuration menu, press <Esc>.

---------------------------INTERFACE STATUS------------------------------

Local Interface (Primary) Remote Interface (Primary)
EIA-530 EIA-530
Actual Rate (bps): 384000 Actual Rate (bps): 384000

Inputs: Outputs: Inputs: Outputs:
RTS: On DCD: On RTS: On DCD: On
DTR: On CTS: On DTR: On CTS: On

LL: Off TM: Off LL: Off TM: Off
RL: Off DSR: On RL: Off DSR: On

Figure 18. Interface Status Screen

For details on the characteristics of your interface, see Chapter 3.

4.14 Link Error Counters

The Link Error Counters screen reports errors that occur on the modem link. See Figure 19 and
Table 18. To view the link errors, follow these steps:

1. From the Main menu type 4, "Link Error Counters," and press <Enter>. The Link Error Counters

screen appears.

2. To reset the timer and counters, press <Tab>.

3. To return to the Main Menu, press <Esc>.

Model 2370 User Manual

4-14

Advertising