Examples

In the following example, the qos evc net-egress command is used to associate a QoS network egress

policy to an EVC and then applied it to interface eth-0-2.

Switch(config)# ethernet evc evc100

Switch(config-evc)# qos-policy net-egress evc110-policy-at-egress-nni

Related Commands

None

32.17 show ethernet evc queue

Use this command to display queue information for EVC. Statistics of each queue will be provided if

queue statistic function is enabled.

Command Syntax

show ethernet evc [EVC-NAME (sap-egress | net-egress)] queue

EVC-NAME: This field is optional, which specifies the name of EVC.

sap-egress: If this argument is specified, only sap-egress queues of the EVC is displayed.

net-egress: If this argument is specified, only net-egress queues of the EVC is displayed.

Command Mode

EXEC Privileged Mode

Usage

None

Examples

In the following example, the show ethernet evc queue command is used to display queue information

for an EVC.

Switch# show ethernet evc queue

EVC: evc100

sap-egress policy: evc110-policy-at-egress-uni

Queue 0

Tail drop mode

Tail drop threshold (drop prec 0 -> 3): 56 60 64 108

Transmit 0 packets, 0 bytes

Drop 0 packets, 0 bytes

Queue 1

Tail drop mode

Tail drop threshold (drop prec 0 -> 3): 56 60 64 108

Transmit 0 packets, 0 bytes

Drop 0 packets, 0 bytes