170.880UK User Manual

Status Indicators

The master section has 4 status LEDs, which indicate as follows.

POWER

When lit, this indicates that the main power is on

PFL/AFL

Pre-Fade or After-Fade Listen is active when lit

LIMIT

Amplifier output clip limiter is active when lit

PROTECT

Amplifier protection is active when lit

The amplifier is not operational when in protect mode, which indicates that a fault is detected.


Main Output Level Meters

The main output level meters comprise a pair of volume ladders with 15 LEDs in each.

These normally display the main left and right output levels unless PFL or AFL is active.

When one or more PFL or AFL buttons are pressed in, these ladders will show the output

of that channel (or those channels) directly.

This enables more detailed analysis of the signal level than can be shown by the channel

signal and clip LEDs alone.


When monitoring any signal levels, it is important to prevent the red LEDs from lighting

for anything longer than a brief flicker. Persistent lighting of the red LEDs indicates

clipping or distortion.



Master Fader Section

The master fader section controls output level for monitors 1 + 2, DSP and main L + R outputs.

62. MUTE

Press to mute the relative output(s)

A red LED lights when muted.

63. PFL / AFL Activates Pre-Fader Listen for monitor

outputs or After-Fader Listen for DSP

Effects.The output of either is routed to

the headphones (33) output and

displayed on the main level meters

(see PFL section above)

A yellow LED lights when active

64. Faders

Output level 60mm fader controls for

Monitors 1 + 2, Effects and Main L + R

Decibel markings (dB) give a reference

to the level setting applied.