SkyView Autopilot In-Flight Tuning Guide - Revision B 8-1

Appendix A: Autopilot Settings –Defaults

ROLL Axis Setting

Minimum

Maximum

Default

TORQUE

10%

100%

100%

SENSITIVITY

1

24

10

ROLL GAIN

0.0

5.0

0.0

BANK ANGLE LIMIT

5

45

30

PITCH Axis Setting

Minimum

Maximum

Default

TORQUE

10%

100%

100%

SENSITIVITY

1

24

10

PITCH GAIN

0.1

3.0

2.0

ALTITUDE GAIN

0.1

2.5

0.6

PULL RATE

1.0

2.0

1.0

VSI GAIN

0.10

2.50

0.6

G ERROR GAIN

0.0

4.0

1.0

G ERROR LIMIT

0.10

1.00

0.25

DEFAULT CLIMB VERT SPD

100 ft/min

3000 ft/min

500 ft/min

DEFAULT DESCENT VERT SPD

100 ft/min

3000 ft/min

500 ft/min

MAXIMUM AIRSPEED

1.30 * Vs1

0.95 * Vne

0.95 * Vne

MINIMUM AIRSPEED

1.30 * Vs1

0.95 * Vne

1.30 * Vs1