Instructions for return – Dynon Avionics EFIS-D6 Installation Guide User Manual

Page 35

Advertising
background image

Appendix

EFIS-D6 Installation Guide

5-5

Problem

Solution

Airspeed is inaccurate by
between 1 and 10 knots (or
equivalent, in other units) at
takeoff speed.

You may recalibrate your EFIS-D6‘s zero pressure value.
With your plane in as windless an environment as possible
(e.g., a hangar), cover both the pitot and static ports with a
sock or cloth to minimize airflow without putting pressure
on the ports. Next, on the EFIS-D6, enter the EFIS main
menu, press SETUP > SPDCAL. When you are confident
that there is no pressure on the pitot and static ports, press
either button corresponding to SET ZERO PRESSURE.
Press YES to confirm you have zero pressure on the pitot
and static ports. You will see a message indicating that the
unit is calibrating. This should only take a few seconds. On
your next flight, verify that the airspeed is what you expect.
To reset the airspeed calibration to factory defaults, enter the
SPDCAL menu, and press RESET DFLTS.

EFIS-D6 displays continuous or
blinking blue screen

Ensure that your power supply is capable of supplying at
least 2 amps and that it is at least 10 volts.
If, after verifying that you have met these two conditions the
unit does not operate normally, it is necessary to contact
Dynon Avionics.

EFIS-D6 screen stays black when
power is applied

Verify Master Switch Power is connected.
Verify Master Switch Power is above 10 volts.

EFIS-D6 indicates over
temperature condition

Provide additional cooling to instrument

EFIS-D6 indicates incorrect
heading

(Re)calibrate the magnetic heading using the procedure
described above.

Internal Backup Battery life is
too short

Verify Internal Backup Battery is charged to above 16 volts
using EFIS-D6 voltmeter.
Re-run capacity test.
Replace battery if insufficient capacity.

Cannot make connection with PC Verify wiring is correct.

Verify no other programs using the COM port are running
on the PC.
Verify latest version of The Dynon Product Support Program
is being used.

INSTRUCTIONS FOR RETURN

If none of the above sections have helped resolve an ongoing issue with your EFIS-D6, please
contact Dynon Avionics to discuss the issue with Technical Support. If, after troubleshooting
with a Dynon representative, the issue cannot be resolved, we will provide you with a Return
Material Authorization (RMA) number to use when shipping the EFIS-D6 to us. If your unit is
still under warranty, the repairs will be performed and the EFIS-D6 will be returned promptly. If
your warranty has expired, the Dynon representative will make arrangements with you and make
you fully aware of the costs before proceeding with the repair.

Advertising