Weight, Plumbing – Dynon Avionics EFIS-D10 Upgrade Installation Guide User Manual

Page 4

Advertising
background image

EFIS-D10A Upgrade Manual

EFIS-D10A Upgrade Guide

Doc Num: 100352-000

Rev. A

6/24/2004

Page

4 of 4

Pin # on EFIS-D10 D25

Action for use of EFIS-
D10A’s serial encoder

4,5,6,7,8,16,17,18,19,20

Remove

13

Wire to transponder serial
input

21

Move to transponder ground
pin

The serial encoder output of the EFIS-D10A reports pressure altitude, that is, altitude unadjusted
for barometric pressure.

WEIGHT

Note that the EFIS-D10A has a slightly different weight from its predecessor. You may need to
plan weight and balance accordingly.

EFIS-D10A:

1 lb 9 oz.

EFIS-D10A + battery:

1 lb 15 oz.

EDC-D10A:

3.6 oz.

PLUMBING

The AOA, Pitot, and Static connections on the back of the EFIS-D10A have not changed from
the EFIS-D10. Simply screw in the plumbing fittings in the same arrangement as before.

Advertising