Start up

Leica DISTO™ D2 762960 en

EN

F

E

P

Display

See drawing {B}
1

Laser "ON"

2

Reference (front/rear/end piece)

3

Pythagoras

4

Timer (self-triggering)

5

Historical memory

6

Area/volume

7

Battery status

8

Units with exponents (

2

/

3

)

9

Intermediate line 2

10 Intermediate line 1
11 Main targets
12 min / max display
13 Info symbol

Start up

Inserting / Replacing Batteries

1

Remove battery compartment lid.
See drawing {C}.

2

Insert batteries, observing correct polarity.

3

Close the battery compartment.

Replace the batteries when the symbol

flashes

permanently in the display.

)

Only use alkaline batteries.

)

If the instrument will not be used for a long

time, remove the batteries as a protection against
corrosion.

Operation

Measuring Conditions

Range

Range is limited to 60 m (197 ft).
At night or dusk and if the target is in shadow the
measuring range without target plate is increased.
Use a target plate to increase the measurement
range during daylight, or if the target has poor reflec-
tion properties!

Target Surfaces

ƽ

CAUTION:
Measuring errors can occur when measuring

toward colourless liquids (e.g. water) or dust free
glass, Styrofoam or similar semi-permeable surfaces.
Aiming at high gloss surfaces may deflect the laser-
beam and lead to measurement errors.

Hazards of Use

ƽ

CAUTION:
Watch out for erroneous distance measure-

ments if the instrument is defective or if it has been
dropped or has been misused or modified.

Precautions:
Carry out periodic test measurements.
Particularly after the instrument has been subject to