Troubleshooting, Specifications, There is no power – Cambridge Audio Azur 540P User Manual

Page 6: There is no sound, There is no sound on one channel, There is a loud buzz or hum, Volume is too loud/quiet

Advertising
background image

6 Azur phono pre-amplifier

There is no power

Ensure the AC power cord is connected securely.

Ensure the plug is fully inserted and is switched on.

There is no sound

Make sure the unit is plugged in.

Check that your turntable is properly connected.

Check that your speakers are properly connected.

Check all connections are secure and correct amplifier input is selected.

Ensure correct cartridge type has been selected (MM or MC).

There is no sound on one channel

Check that your speakers are properly connected.

Check all connections are secure.

There is a loud buzz or hum

Check turntable or tone arm for ground and connection

lead fault.

Ensure no connections are loose or defective.

Ensure that your turntable is not too close to the amplifier.

Volume is too loud/quiet

Check cartridge type matches input type. If a MC cartridge

is connected through the MM inputs, volume will be very

quiet (and vica versa). Note that it is possible to obtain

high level MC cartridges which are designed for an MM

input.

TROUBLESHOOTING

540P

640P

640P

(MM)

(MC)

Max power consumption

5W

5W

5W

Gain @ 1kHz

39dB

39dB

55dB

Nominal output

300mV

300mV

300mV

Sensitivity for

3.35mV

3.35mV

0.5mV

nominal output

THD 20Hz-20kHz

<0.009%

<0.005%

<0.002%

RIAA curve accuracy

<+/-0.65dB

<+/-0.3dB

<+/-0.3dB

25hz-20kHz

20Hz-50kHz

20Hz-50kHz

(subsonic filter off)

Signal to noise ratio

>85dB

>86dB

>72dB

using Audio Precision RIAA-1

with grounded inputs

Crosstalk @ 20kHz

>76dB

>83dB

>69dB

Dimensions (HxWxD)
mm

46 x 215 x 133

46 x 215 x 133

46 x 215 x 133

inches

1.8 x 8.5 x 5.2

1.8 x 8.5 x 5.2

1.8 x 8.5 x 5.2

Weight
kg

0.8

0.9

0.9

lbs

1.8

2

2

SPECIFICATIONS

Advertising