User's Guide to DISTO Online

Troubleshooting

••••

29

Troubleshooting

DISTO online did not detect a Leica DISTO

Can't open COMx:. The device is not available or
not existing.

If DISTO online only display such line on page information there may be
following errors:

The serial ports COM1, 2 etc. are missing actually. Maybe check your BIOS set-
up.

The interface COM1, 2 etc. is occupied by another program. That could be e.g. a
driver for a modem, a driver for a mouse, a synchronisation program for a Palm,
a Psion or a Windows CE Organiser etc.. Check, whether you installed such a
program, and configure you it in such a way that the interface is released, or
uninstall the appropriate program.

Port COMx: opened. Searching for DISTO...no
DISTO found.

This error may have many reasons:

At this port there is no DISTO connected.

The interwiring between DISTO and PC could be incorrect, check your data
cable.

The interface parameters of the Leica DISTO do not correspond to the factory
settings. In order to reset the parameters consult the manual to your DISTO.