Equipment checklist for static and rapid, Static measurements using system 500 – Leica Geosystems GPS System 500 - Getting Started with Static and Kinematic Surveys User Manual

Page 7

Advertising
background image

7

Static and Kinematic Surveys-2.0.0en

Equipment checklist for Static and Rapid-Static measurements using System 500

Batteries are needed to power the

sensor. Standard are two camcorder

batteries which are plugged into the

backside of the sensor and power the

unit for about 6 hours.

Warning
Brand new camcorder

batteries need about 5

charging cycles before

reaching the full capacity. It is

highly recommended to fully

charge and decharge

camcorder batteries for 4 to 5

times before start-ing using

them for practical fieldwork.

This is easily accomplished

by plugging them into the

sensor and having the sensor

turned on until the sensor

switches off automatically

once the batteries get flat.

Then simply recharge them

and repeat this exercise.

Equipment checklist

If you want to use System 500 for

Static or Rapid-Static survey then the

minimum equipment you need is a

pair of System 500 units.

Each unit comprises a SR510 or

SR520 or SR530 sensor.

A single frequency SR510 sensor

requires an AT501 single frequency

antenna; SR520 and SR530 sensors

need to be connected to a dual-

frequency antenna, normally the

AT502 standard antenna or - for

utmost accuracy - high precision

chokering antennas: either a AT503

or AT504.

An antenna cable is needed to

connect the sensor and the antenna.

A TR500 terminal - a keyboard &

display device - is needed to easily

start the operation, check system

status and manipulate sensor

parameters.

6

7

Advertising