Carrier 58TMA User Manual

Carrier Kiln

Advertising
background image

58TMA, 58TUA

Deluxe 2-Speed Gas-Fired

Induced-Combustion Furnace

Service and Maintenance Instructions

For Sizes 040-135, Series 100

NOTE:

Read the entire instruction manual before performing any

service or maintenance.
This symbol

indicates a change since the last issue.

Index

Page

SAFETY CONSIDERATIONS..................................................1-2
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

PROCEDURE ...........................................................................2

CARE AND MAINTENANCE..................................................2-7

Air Filter Arrangement..........................................................2-3
Blower Motor and Wheel......................................................3-4
Cleaning Heat Exchanger......................................................4-6
Electrical Controls and Wiring .............................................6-7
Troubleshooting ...................................................................7-10
Unit Wiring Diagram................................................................8
Service Label ............................................................................9
Troubleshooting Guide ...........................................................10

SAFETY CONSIDERATIONS

Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified person-
nel should install, repair, or service heating equipment.

Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in the literature, tags, and
labels attached to or shipped with the unit and other safety
precautions that may apply.

Follow all safety codes. In the United States, follow all safety
codes including the National Fuel Gas Code NFPA No. 54-
1992/ANSI Z223.1-1992. In Canada, refer to the current edition of
the National Standard of Canada CAN/CGA-B149.1- and .2-M91
Natural Gas and Propane Gas Installation Codes. Wear safety
glasses and work gloves. Have fire extinguisher available during
start-up and adjustment procedures and service calls.

Recognize safety information. This is the safety-alert symbol

.

When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage.

Fig. 3—Model 58TUA Upflow

A94085

Fig. 2—Model 58TMA

Downflow

A94086

Fig. 1—Model 58TMA Horizontal

A94087

®

ama

CANADIAN GAS ASSOCIATION

A PP R O VED

R

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

6a 8a

PC 101

Catalog No. 565-845

Printed in U.S.A.

Form 58T-3SM

Pg 1

1-95

Replaces: 58T-2SM

Advertising