Disa ringing time assignment, Toll restriction code check, Co indicator assignment – Panasonic KX-T206 User Manual

Page 9: Pulse break ratio assignment, Hookswitch flash time range assignment, Dial start time, Pulse speed selection, Note, System programming, Other programs (continued)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

System Programming

Other Programs (continued)

DISA Ringing Time Assignment

Sets the time to forward a call sent by the DISA
feature to other extensions. If the call is not

answered by the designated extension within the

programmed time, the call is forwarded to

extensions which are not assigned as “DIS­
ABLE” in the #04/#74 COl Ringing Assignment

(Day/Night) and #05/#75 C02 Ringing Assign­
ment (Day/Night). If “DISABLE” is selected in

this program, the telephone at the designated

extension rings for 60 seconds and the call is not
forwarded.

Input Format:

#60 [A]

• [A]=0: DISABLE /1:10 SEC/

2: 20 SEC (default)/ 3: 35 SEC

• Toll Restriction Code Check

Assigns whether “ ^ ” or “#” is to be checked or
not when a user dials them in the Toll Restriction
code.

Input Format:

#62 [A]

• [A]=0: DISABLE/ 1; ENABLE (default)

• CO Indicator Assignment

Assigns whether an incoming CO call indicates

or not on the CO button. Also it allows an

extension user to answer the call by pressing the

CO button when “DISABLE” is selected in the

#04/#74 “COl Ringing Assignment” or the #05/
#75 “C02 Ringing Assignment” program.

Input Format:

#63 [A]

• [A]=0: DISABLE (The indicator lights red and

a user cannot answer the
call.)

1: ENABLE (The indicator is flashing and

a user can answer the call.)
(default)

• Pulse Break Ratio Assignment

Assigns the pulse break ratio during dial pulsing.

Input Format.

#64 [A]

• [A]=l: 66% (default)/ 2: 60%

Hookswitch Flash Time Range
Assignment

Sets the hookswitch flash time range.

Input Format:

#65 [A]

• [A]=l: 80-1000ms (default)/ 2: 80-150ms

Dial Start Time

Sets the time the system waits before dialing
after a CO lined is seized.

Input Format:

#66 [A]

• [A]=l: 800 ms (default)/ 2: 2000 ms

Pulse Speed Selection

Sets the pulse speed for CO lines.

Input Format:

#68 [A]

• [A]=l: 10 EPS (default)/ 2: 20 PPS

Note

You cannot check the assignments of the above programs by setting the MEMORY switch to
“PROGRAM”, and entering “#” and the program address.

27

Advertising
This manual is related to the following products: