Wiring with No Telco Line

Wiring with No Telco Line

The unit can be a stand alone system that allows communication between the unit and a resident’s phones.

Single Unit

Tip

Ring

Tip

Ring

RES

TELCO

Use 18-24 AWG

2 twisted pair

Output Board

(See page 6)

NOTE: Ringer Equivalence Number (REN) of “5” maximum.

Never run Telco wires and High
Voltage wires
in the same
conduit. The high voltage wires
may interfere with the Telco
wires, possibly causing the
system to malfunction.

Multiple Units (Up to 7)

Tip

Ring

Tip

Ring

RES

TELCO

Tip

Ring

Tip

Ring

RES

TELCO

To next unit (Unit ID 3 then 4 etc.)

Use 18-24 AWG

2 twisted pair

IMPORTANT: You must program the unit ID's for each
unit wired in the series. See
Keypad Programming Manual.

IMPORTANT: Only disable the Telco mode of the unit farthest
away from the house. See
“Disable Telco Mode” in the
Keypad Programming Guide.

Unit ID 1

Output Board

(See page 6)

Unit ID 2

Output Board

(See page 6)

Home Phone

NOTE: Ringer Equivalence Number (REN) of “5” maximum.