Model
Heat Input Rate (BTUH):

140000 *

119,000

105,000

84,000

Nominal Thermal Efficiency (%):
Minimum Heating Capacity (BTUH):

114000 *

98,000

87,000

70,000

Nominal Temp. Rise (deg. F.):
Minimum AFUE Rating (%):
Gross Heat Exchange Area (sq. ft.) ** :
Casing Height (in.):
Casing W idth (in):
Casing Depth (in.):
Nominal Flue Outlet Dia. (in.):

Supply Air Outlet Size (in. x in.):
Return Air Inlet Size (in. x in.):

Approx. Shipping W eight (lb.):
Electrical Requirements (VAC/Hz/Ph):
Total Current (Amps.):
Max. Fuse Size (Amps.):

Blower Specifications:
Blower Motor Size (HP):

Motor Type & Number of Speeds:
High Speed Airflow (SCFM) @ 0.4 in.
W .G. External Static Pressure:

Air Tube Length (in.):
Burner Head Type:
Fuel Type:
Nozzle Rating for Beckett AF (GPH):

1.00

0.85

0.75

0.60

Nozzle Rating for Beckett NX (GPH):

0.85

0.65

0.60

0.50

Nozzle Rating for Carlin EZ-1HP (GPH):

0.85

0.75

0.65

0.50

Nozzle Rating for Riello 40-F3 (GPH):

0.90

0.80

0.70

0.55

Spray Angle (Deg.) *** :
Spray Pattern ***:
Oil Pump Pressure (PSIG) *** :
Ignition Control Type:
Pre/Post Purge Feature(s):
Automatic Oil Solenoid Valve:
Combustion Chamber Type:

Clearances to Combustible Materials
(Minimums)
Sides (in.):
Top (in.):
Front (in.) ** :
Rear (in.):
Flue/Vent Pipe (in.):
Supply Plenum Surfaces (in.):

* with Riello 40-F3 burner the maximum heat input rate is 133,000 BTUH. The corresponding heating
capacity will be approx. 109,000 BTUH.
** for front flue model / for rear flue model
*** with Beckett AF burner / with Beckett NX burner / with Carlin EZ-1HP burner / with Riello 40-F3 burner

Burner Specifications:

None

9

Riello pressure atomizing type, Model 40-F3 (Alternate)

Preformed, refractory (ceramic fiber matrix material)

5.875, effective

Fixed, flame retention

# 2 distillate (domestic heating oil)

Hollow / Semi Solid / Hollow / Hollow

130 / 150 / 140 / 150

80 / 60 / 60 / 60

84.2

Interrupted, Direct Spark

None

15

R.W . Beckett pressure atomizing type, Model AF (Standard)

R.W . Beckett pressure atomizing type, Model NX (Alternate)

Carlin Combustion pressure atomizing type, Model EZ-1HP (Alternate)

Directly-driven, DW DI, FC centrifugal, w/ 10 in. dia. wheel

3

3
3

8 (front flue) / 3 (rear flue)

3

Crown Furnace Oil-Fired Lowboy Furnace Specifications

41.5

Air Filter Quantity & Size (in. x in.):

CLBF 68-112 (Front Flue) or CLBR 68-112 (Rear Flue)

27.8 (front flue) / 30.0 (rear flue)

37.5 (front flue opens upward)

Height from Floor to Center of Flue (in.):

47

6

20 x 20

85

82.0

120 / 60 / 1

10.2 (w/ R.W . Beckett oil burner)

300

31 (rear flue exits horizontally rearward)

22.25

20 x 12.5

two, 10 x 20 ea.

Permanent split capacitor, 4

1/2

1400