Technical Specifications

Tower Dimensions (HxWxD) 17.65 x 6.6 x 17.61 in/44.83 x 16.76 x 44.73 cm

System Unit

Weight

(standard configuration)

26 lbs/12 kg

Power

Supply

Operating Voltage Range

90 VAC to 264 VAC

Rated Voltage Range

100 VAC to 120 VAC; 200 VAC to 240 VAC

Rated Line Frequency

50 Hz to 60 Hz

Rated Input Current

8.6A @ 115 VAC; 4.3A @ 230 VAC

Maximum Rated Power

460-Watt output

Physical Dimensions

5.9 x 3.85 x 6.3 in/15 x 9.8 x 16 cm

Weight

4.5 lbs/2.05 kg

Temperature

(

Values are subject to change

)

Operating 50

°

to 95

°

F/10

°

to 35

°

C

Non-operating 4

°

to 140

°

F/–15

°

to 60

°

C

Humidity (non-condensing)

(

Values are subject to change

)

Operating

20% to 80%

Non-operating

10% to 90%

Maximum Altitude

(nonpressurized)

Operating

10,000 ft/3,048 m

Non-operating

30,000 ft/9,144 m

Compaq Easy Access Keyboard Dimensions (HxWxD)

18.3 x 6.3 x 1.4 in/465 x 160 x 36 mm

Weight

Approximately 2 lbs/0.9 kg

Electrical

Operating Voltage

+

5VDC

±

5%

Power Consumption

50 mA maximum (with 3 LEDs on)

System Interface

PS/2 mini-din connector

ESD

CE level 4, 15 kV air discharge

EMI-RFI

Conforms to FCC rules for a Class B computing
device

PC98

Functionally compliant

Mechanical

Languages

30

+

available

Keycaps Low-profile

design

Switch Actuation

55 g nominal peak force with tactile feedback

Switch Life

20 million keystrokes (using Hasco modified tester)

Switch Type

Contamination resistant membrane

Key Leveling Mechanism

For all double wide and greater length keys

Cable Length

6 ft/1.8 m

PC98-99

Mechanically compliant

Acoustics

50 dBA maximum sound pressure level

Environmental

Operating Temperature

50

°

to 122

°

F/10

°

to 50

°

C

Non-operating Temperature

22

°

to 140

°

F/

30

°

to 60

°

C

Operating Humidity

10% to 90% (non condensing at ambient)

Non-operating Humidity

20% to 80% (non condensing at ambient)

Operating Shock

40 g, 6 surfaces

Non-operating Shock

80 g, 6 surfaces

Operating Vibration

2 g peak acceleration

Non-operating Vibration

4 g peak acceleration