PLACEMENT

The room heating unit was designed to be mounted in one of two places: on the floor or up on the wall. If
installing on the floor, normally, standard flooring systems with any type of covering, i.e. wood floor, carpet,
linoleum, will be sufficient; but, heater weight must be considered. If in doubt, consult a building contractor or
an architect. (See Table 2 for weight and physical dimensions of room heating unit being installed.) If install-
ing the heater at a height above the floor, a special wall mounting bracket must be used. This wall mounting
kit does not come standard with the heater and must be ordered special. (Order item #1190036.)

IMPORTANT: The heater must be securely attached to wall studs.

Since the intake grill for the room air is located at the bottom of the heater, caution should be exercised when
installing the heater on extremely thick carpet. Any contact with the intake grill could block the air passage
through the brick core and inhibit the heating capabilities of the room unit.

Avoid installing the heater near sources of extreme heat or cold so the built-in room temperature sensor can
sample proper room air temperature.

CLEARANCE REQUIREMENTS

Allow a minimum of 2 inches of clearance from the sides of the heater and a
minimum of 12 inches from the top of the heater. There is no back clearance
as the heater's back panel surface mounts to the wall. (See Figure 7.)

If enclosing the room heating unit in a wooden cabinet or recessing it into a
wall, allow 2 inches clearance on sides and 12 inches on top. Do not
enclose or otherwise obstruct access to the heater's front panel and the air
intake and discharge grills. Objects such as curtains, furniture, or bed
covers must be kept a minimum of 4 inches from all room heating unit
surfaces and 12 inches from the grills.

If there is less than a 12" clearance on the right side of the room heating unit, we recommend

installing a remote wall mounted room temperature sensor. (Order item #1302024.)

Operating the Heater

Operating the Heater

Operating the Heater

Operating the Heater

Operating the Heater

(cont'd)

(cont'd)

(cont'd)

(cont'd)

(cont'd)

1

10

2

F

F

F

F

F

Setting the Heater to "OFF" and turning it back "ON" when Using Manual Charge Control

Step 1

To turn the heater "OFF", hold the M button until room temperature set point appears on the TEMPERA-
TURE digits of the face plate.

Step 2

Use the

ò

arrow button to decrease the room temperature set point until the control panel face plate

displays "OFF".

Step 3

To turn the heater back "ON", press and hold the M and the

ñ

arrow buttons at the same time. When

room temperature set point displays on the face plate, let go of the M button. Use the

ñ

arrow button to

adjust room temperature to the desired set point.

Installing

Installing

Installing

Installing

Installing The Heater

The Heater

The Heater

The Heater

The Heater

NOTE

12" Min.

Clearance

Above Unit

12" Min.

Clearance

air intake

grill

air discharge

grill

2" Min.

Clearance

FIGURE 7