Operating the furnace – Steffes DLF40B User Manual

Page 8

Advertising
background image

FURNACE START-UP 

On start­up of the furnace, you may experience some odors relating to first time operation of the heating compo­ 
nents.  There may also be an odor associated with dust accumulation in the system if the furnace is shut­down for 
an extended period of time.  Upon restart, allowing the furnace to charge to its maximum brick core charge level 
will help expel these odors in a timely manner. 

During operation, it is normal for the furnace, like any heating system, to produce expansion noises. These noises 
are the result of the internal components reacting to the temperature changes they are exposed to. 

ROOM TEMPERATURE CONTROL 

Room temperature is adjusted at the wall thermostat.  With a heat call to the thermostat, the core blower in the 
furnace is energized to circulate hot brick core air through the furnace’s heat exchanger.  The core blower 
automatically adjusts its' speed (low or high) in relation to the brick core temperature.  The blower operates in low 
speed with a hot brick core and in high speed with lower brick core temperatures. 

After the brick core air warms the heat exchanger, the supply air blower is energized.  The supply air blower 
circulates the room air through the heat exchanger to warm it; and, then, delivers it back into the living space 
through the duct system. 

The delay between the core blower operating and the supply air blower being energized ensures only warm, 
comfortable, even heat is being delivered into the living area.  Intermittent supply air blower operation may occur 
with lower brick core temperatures in an effort to maintain a constant temperature and even distribution of heat 
into the living area. 

Some thermostats incorporate a room temperature set back feature which allows for room temperature to 
automatically be set back a specific number of degrees at specified times.  If using a thermostat with this feature 
in a program where the power company has 8 or more consecutive hours of control, it is important to bring the 
room temperature back to the desired occupied temperature a minimum of three (3) hours before the off­peak 
(charge) period ends.  This will ensure optimum heat storage for maintaining the desired room temperature 
throughout the on­peak (control) period. 

BRICK TEMPERATURE CONTROL (CORE CHARGING) 

The amount of heat stored in the brick core of the furnace is regulated automatically in relation to outdoor tem­ 
perature and to its control panel settings.  The outdoor temperature sensor that ships with the furnace as standard 
equipment MUST be mounted outside.  It provides temperature information to the furnace for proper brick core 
charging. 

In standard configuration from the factory, the outdoor sensor signals the furnace to maintain a level 1 (1/3) brick 
core charge at a 55 

F outside temperature, a level 2 (2/3) core charge at 35 

F, and a level 3 (maximum) core 

charge at 15 

F.  At temperatures above 55 

F, the furnace will not maintain a core charge; however, if there is a 

heat call from the thermostat during off­peak times, 1/3 of the elements will be energized to provide heat for the 
duration of the heat call.  (Refer to Table 1, Brick Core Charging Schedule, for more information on charging 
levels in relation to outdoor temperature and the furnace control panel settings.) 

If  outdoor  temperature  charging  set  points  other  than  the  standard  configuration  are  pre­ 
ferred,  the  sensor  must  be  specially  ordered  from  the  factory. 

Operating the Furnace

7

2

3

1

NOTE