Steffes Transmitter User Manual

Page 4

Advertising
background image

TABLE OF CONTENTS

General Operation...................................................................1

Installation............................................................................ 1-4

Line Voltage Connections ............................................... 1-2
Peak Control ........................................................................2
Circuit Board Configuration ................................................2
Outdoor Temperature Sensor...............................................3
Indicator Lights....................................................................3
Room Temperature Set Back...............................................3
Anticipated Peak ..................................................................4

Dip Switch Settings.............................................................. 4-6

Installer’s Final Check Out Procedure.............................. 7-8

Typical System Wiring Diagram (Single Phase)...................9

Typical System Wiring Diagram (3-Phase).........................10

FEATURES

The PLC transmitter is an accurate and reliable device offering the

following features:

w Operates on 120V or 208V/240V, single phase.

w Pre-wired 16 AWG leads for line voltage field connections.

w A 6” x 6” x 3” rainproof metal enclosure with power company

seal/lockout provision for indoor or outdoor installations. A three

phase system in a 12” x 6” x 3” rainproof metal enclosure is

available as a special factory order.

w Fifteen (15) selectable communication channels.

w Wireless control of an unlimited number of Steffes microprocessor

based heating systems and any controllable devices with the

correlating receiver.

w Capable of transmitting:

é Peak Control Signals

é Outdoor Temperature Information (Automatic Charge Control)

é Room Temperature Set Back Information (requires an external

signaling device, not included)

é Anticipated Peak (pre-peak) Control Signals

TYPICAL SYSTEM WIRING DIAGRAM

SINGLE PHASE (208/240 Volt or 120 Volt)

NOTES:

1. To ensure proper communications between the PLC transmitter and the

controllable electrical loads, the transmitter MUST be grounded.

2. The system grounding and bonding must be sized and installed in

compliance with all applicable codes.

3. The transmitter in this diagram is shown connected directly to the service

panel. However, any appropriately sized uninterrupted branch circuit

can be used to power the transmitter

2

1

4

5

6

7

8

3

E

ROOM TEMP SETBACK (OPTIONAL)

A-PEAK (SPECIAL APPLICATIONS)

LOW VOLTAGE HOT

208/240V

LOW VOLTAGE

CONNECTIONS

20

20

15

2

20

1

240VAC SOURCE

R

R

O

C

K

ER

D

O

W

N

120V

OR

N O

LINE

VOLTAGE

CONNECTIONS

SENSOR

Power Company.

Set-Back

Room

4

3

Anticipated Peak

Control Switch.

Utilized By the

Control Switch.

Utility Peak

PEAK

SENSOR

OUTDOOR

A

P

O

S

O

S

(OPTIONAL)

OUTDOOR

REMOTE

( Optional )

Temperature

Only if being

Service Panel

9