Dip switch settings, Single pole or double pole configuration) – Steffes Mini Receiver User Manual

Page 5

Advertising
background image

RELAY 2

30 AMP

BLACK

LOAD # 1

LOAD # 2

CONTROLLED

TO

CONTROLLED

TO

BLACK

RED

RELAY 1

30 AMP

OVERRIDE

LIGHT

TRANSFORMER

DIP SWITCHES

(See Note 1)

RED

LIGHT

INDICATOR

MICROPROCESSOR

L2

L1

CONNECTIONS

LINE VOLTAGE

(See Note 3)

120 VOLT

240 120 L1

( )

OR

208/240 VOLT

277V

ORDER

SPECIAL

240 120 L1

L2

L1

/ / / /

(See Note 2)

2-POLE OPTION

(See Note 4)

LINE VOLTAGE WIRING AND CIRCUIT BOARD

CONFIGURATION DIAGRAM

(single pole or double pole configuration)

This Device MUST be Grounded.

Grounding and Bonding is not shown in this Diagram.

For reference to the “NOTES” listed in this diagram, refer to the Notes

section on page 8 in this manual.

DIP SWITCH SETTINGS

DIP SWITCH 1: ANTICIPATED PEAK (PRE-PEAK) OPERATION MODE

This dip switch determines how an anticipated peak (pre-peak) signal will affect

the mini receiver’ s relay(s). For power companies desiring to control loads

separately using multiple signals, this dip switch can be used to do peak control

of devices on a separate rate/control strategy.

FACTORY DEFAULT SETTING = OFF

Off = Relay(s) will not respond to an anticipated peak (pre-peak) signal.

On = Relay(s) will be activated by an anticipated peak (pre-peak) signal.

The peak signal is priority signal. When a peak signal is being

received, no other signal will be recognized.

DIP SWITCH 2, 3, 4 & 5: PLC CHANNEL SELECTION

The mini receiver can receive information on one of fifteen channels, depending

on which channel the transmitting device is set to transmit on. The mini receiver

and the transmitting device MUST be set to the same channel for proper

communication to occur.

To select the Power Line Carrier channel desired, use the chart below and set dip

switches 2, 3, 4,and 5 to the proper positions.

FACTORY DEFAULT SETTING = No PLC Channel selected (2 OFF, 3 OFF, 4

OFF, 5 OFF)

A specific channel must be selected at time of installation.

C

HANNEL

D

IPSWITCH

2

DIPSWITCH

3

DIPSWITCH

4

DIPSWITCH

5

0

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

12

OFF

OFF

ON

ON

13

ON

OFF

ON

ON

14

OFF

ON

ON

ON

15

ON

ON

ON

ON

6

3

Advertising