Chromalox PF497-1 User Manual

Chromalox, Installation, operation, Renewal parts identification

Advertising
background image

DATE

SALES

REFERENCE

DIVISION

SECTION

Chromalox

®

(Supersedes PG422-1)

PF497-1

DRA

161-304812-001

NOVEMBER, 2002

4

RENEWAL PARTS IDENTIFICATION

Installation, Operation

and

(Supersedes PF-497)

© 2010 Chromalox, Inc.

Specifications – Table 1

GENERAL

IMPORTANT:
SAVE THESE INSTRUCTIONS

Risk of fire. Do not use as a residential or house-
hold heater.

Hazard of Fire or Discoloration of Temperature
Sensitive Fabrics. Do not use as a residential or
household heater. Keep combustible material and

such fabrics away from heater. Do not operate
heater where flammable vapors, gases or liquids
are present. Heaters in the heat mode should not
be operated in room temperatures above 80°F. Fan
motor is not designed to operate in ambients below
-40°F.

To avoid personal injury read “IMPORTANT
INSTRUCTIONS” on page 2 before installation or
operation of heater.

Keep electrical cords and combustible materials,
such as drapes and other furnishings, away from
heater.

Electrical Data (60 Hz)

Dimensions (In.)

Model

Volts

kW

Phase

Amps* 1/3 Ph

BTU

Height

Width

Depth

DRA-07-83

208

7.5

1 and 3

36.3/21.0

25,590

34.25

27.5

25

DRA-07-23

240/208

7.5/5.6

1 and 3

31.5/18.3**

25,590

34.25

27.5

25

DRA-10-83

208

9.75

1 and 3

47.1/27.3

33,267

34.25

27.5

25

DRA-10-23

240/208

9.75/7.3

1 and 3

40.8/23.7**

33,267

34.25

27.5

25

DRA-15-83

208

15

3

41.8

51,180

34.25

27.5

25

DRA-15-23

240/208

15/11.2

3

36.3**

51,180

34.25

27.5

25

DRA-15-43

480

15

1 and 3

31.4/18.2

51,180

34.25

27.5

25

DRA-15-63

600

15

1 and 3

25.2/14.6

51,180

34.25

27.5

25

DRA-20-23

240/208

19.5/15

3

47.1**

66,534

34.25

27.5

26.5

DRA-20-43

480

20

1 and 3

42.0/24.4

68,240

34.25

27.5

26.5

DRA-20-63

600

20

1 and 3

33.5/19.4

68,240

34.25

27.5

26.5

DRA-30-43

480

30

3

36.3

102,360

34.25

27.5

26.5

DRA-30-63

600

30

3

20.1

102,360

34.25

27.5

26.5

* = Includes motor amps
** = Ratings shown are for 240V, 208V amperage is 86% of 240V value.
Models shown as 1 and 3 phase are factory wired for 3 phase operation and can be field wired for single phase.

Portable Industrial

Unit Blower Air Heater

Type DRA

Advertising