Adaptive Technologies PM-SAFETY-6DOWN User Manual

Polestar, Pm-safety-6down

Advertising
background image

© 2007 Allen Products Company, Signal Hill, CA 90755 USA (562) 424-1100

REV0 021308

Figure 2: Shown With PM-BAND-30 installation

Front view

Rear view

Figure 1:

Figure 3A: Single safety cable application

Figure 3B: Double safety cable application

PoleStar

TM

PM-SAFETY-6DOWN

Installation Instructions

Safety Cable Anchor Point

T

hank you for choosing the PoleStar

TM

PM-SAFETY-6DOWN safety cable anchor point.

This weatherized safety cable anchor point is designed to adapt the 2” and larger poles or
column to provide an anchor point for safety cables attachment.

Important:
Mounting overhead systems require experienced professionals. Improperly installed

audio equipment can result in property damage, personal injury, death and/or liability
to the installing contractor.
Do not install if in doubt about the integrity of the mounting
structure.

Caution: Due to the wide variety of mounting structures, environments, materials, mounting
methods, the installing contractor have to exercise good judgment in selecting the proper
mounting area and hardware.

Follow these instructions for the most efficient and safest mounting results.

Package Contents:

Qty Description

Qty Description

1 pc.

PM-SAFETY-6DOWN

2 pcs

Flat washer, ½

1 pc

½-13 Eyebolt,zinc

1 pc

Nylock Nut, ½-13

1 pc

5/16 shackle,zinc

1 pc

Instruction sheet

Step 1.
Assemble eyebolt to the center hole of the channel using the supplied flat washers and
nylock nut. Tighten nut , but make sure that the eyebolt can still rotate easily (Figure 1).

Step 2. Secure Anchor point:
Attached the PM-SAFETY-6DOWN to a pole using the selected type of banding strap
(Figure 2). Makes sure the selected banding strap is capable of supporting the load.
See PM-Band-Series Instruction sheets.
For 2”-6” poles use PM-BAND-20S (150 lbs working load)
For 4”-9” poles use PM-BAND-30 (300 Lbs working load)
For 4-19” poles use PM-BAND-60 (300 Lbs working load)
For 4”-28” poles use PM-BAND-90 (300 Lbs working load)

Figure 1 shows an example of a PM-BAND series type of

installation: PM-Band Series sold separately

Step 3. Attach Safety Cable to PM-SAFETY-6DOWN
Attach the loop of the safety cable or the CC-0096 adjustable
length safety cable
to the eyebolt of the PM-SAFETY-6DOWN
using the supplied 5/16 shackle (Figure 3A and 3B).