4.4.7

Schematic for 1 MIDI In and 2 MIDI Outs

MIDI Out 1

MIDI Out 2

Opto

App.

UARTs

R

LK/ACT

ALYSEUM

ALeX

App.

Power

5V to 18V

GND or 0V

MIDI In

Input & Output voltage ratings: 3.3V to 5V (1 logic) and 0V (0 logic)

4.4.8

Power supply connection

Mistakes in the wiring of the supply may destroy the ALeX module and the power supply of
your equipment
Check with a Voltmeter the supply voltage inside the equipment. Try to locate the Digital
positive between 5V minimum and 18 V DC maximum, and connect it the blue wire.
Do not forget connecting the brown wire to a Digital 0V/ground point on the PCB.

4.4.9 Powering

up

● Reread and check carefully all the installation steps.
● The LED should flash briefly as you switch on the supply of your equipment.
● Connecting an active network cable should make the Network LED blink according to

the traffic.