PAGE 5

Technical support (650) 384-0000

www.avalanwireless.com

AW2400-SPEC

User’s Manual

(Note that the IP address and other parameters for your unit will be different from

those in the picture.)

5. Enter the password (default is “password”) and click “Login”. You will then see

the main spectrum analyzer window similar to this:

6. The spectrum analyzer controls are quite simple:

• The “Scan Now” button initiates a spectrum scan.

• The Automatic Scan Interval dropdown allows you to select the time between

scans. Note that more samples per point and finer frequency resolution will

take longer, up to 2 seconds for a step size of one and 256 samples per point.

• The Samples Per Point dropdown controls how many measurements are taken

at each frequency and averaged together.

• The Frequency Step Size dropdown controls the frequency resolution of the

scan. A step size of one provides about 100 samples across the range, with

about 1 MHz per step (actually 1.0417 MHz).

7. The graph shows both peak and average dBm readings. Optionally, you can dis-

play markers on the graph corresponding to the 29 channels that AvaLAN radios

employ in the 2.4 GHz band. If you wish to make a hard copy of the graph, you can

use your browser printing capability or any of a number of screen capture methods.