Rear panel features, Ac power, Fuse – Aviom MH10f User Manual

Page 23: Backup dc power - mh10f, Ac power fuse backup dc power ‑ mh10f

Advertising
background image

16

r

eAr

P

ANel

F

eAtures

Rear Panel Features

All MH10/MH10f rear‑panel features and functions are described in this

section. Individual differences between the MH10 and MH10f will be called

out as needed.

AC Power

Pro64 modules use switching power supplies that can operate at 100‑240V

and from 50‑60Hz, meaning that they can be used with most of the world’s

AC power systems by simply changing the line cord. The MH10/MH10f is

equipped with a standard grounded IEC power inlet (with fuse) which can

accept the interchangeable IEC power cord.

Access the fuse by pressing on the spring-loaded hatch beneath the AC

power inlet.

Fuse

The fuse holder is spring‑loaded and has space for two fuses, one main and

one spare (optional). Press the fuse holder cover to access the fuse. When

checking or replacing a fuse, always power off the Pro64 unit and remove

the line cord from the AC power source.

Always replace the fuse with one of the same rating as that being changed.

Backup DC Power - MH10f

For applications where a backup power source is required, the MH10f is

equipped with a backup DC power inlet using a locking 4‑pin XLR jack. A DC

power supply capable of outputting 24VDC ±5% at 1 amp is required. In the

locking XLR plug, connect pin 1 to ground and pin 4 to the 24VDC supply.