A positive-going pulse of greater than 250 msec is
treated as a level-sensitive trigger. Shorter pulses
are treated as a pulse-sensitive trigger. The
minimum detectable pulse length is 200

µ

sec.

During level-sensitive operation, applying a voltage
to the trigger input will set the amplifier to the

“Operate” mode. When the applied voltage drops to

zero, the unit reverts to the low-power consumption
mode.

In the pulse-sensitive mode, a positive-going pulse
will toggle the amplifier between the low-power
consumption and “Operate” states, duplicating the
action of the right-hand front-panel button when it
is held for three seconds.

The front-panel button remains operative when
the trigger input is used. Therefore, using the
front-panel button will put the amplifier out of

“sync” with the trigger control device. When

used with level-sensitive trigger operation, the
next trigger action will automatically restore

“sync”. However when using pulse-sensitive

trigger operation, “sync” can only be restored by
pressing the front-panel button a second time.