In Case of

Trouble

Should the Ayre K-1x preamplifier ever fail to operate
properly, please check the following:

Symptom: Remote control not

working.

Check the condition of the batteries (2 x AAA) located in
the remote control.

Symptom: No sound, even

though status indicator is

glowing blue.

Check all connections on the rear panel to make sure they
are secure.

Symptom: Status indicator

lamp not lit.

1) Be sure that the power supply unit is connected to a
working AC outlet.

2) Check the AC line fuse.

To check the fuse, locate the rectangular fuse holder
mounted on the rear panel of the power supply. Press
downwards on the top edge, then pull outward. There are
two fuses mounted in the fuse holder. The inner one is the
operating fuse, and the outer one is a spare.