Blue Sky Solar Boost 3024iL DUO-Option User Manual

Page 4

Advertising
background image

Page 4 of 4

Clamp on ferrite suppressor noise

The 3024iL is shipped with two clamp on ferrite suppressors to minimize EMI radiation and susceptibility. One is placed around both
battery wires, and the second is placed around the battery temperature sensor and remote display wires. If the 20A Load output drives
the dump load directly it is possible that the battery wire suppressor may emit a 100Hz buzzing noise resulting from the 100Hz PWM
diversion current.

This noise can be eliminated by also routing the dump load wire from the 20A Load output through the battery wire suppressor in the
same direction as the battery wires. If wire size is such that all three wires cannot fit through the existing battery wire suppressor an
additional suppressor may be used. One suppressor should be placed around the BAT- wire alone. The other should be placed around
both the BAT+ wire and the dump load wire. Routing both the BAT+ wire and the dump load wire through the same suppressor in the
same direction cancels 100Hz magnetic field in the suppressor which eliminates the noise. Additional suppressors may be ordered as
BSE part number 523-0005-01.

Wind/Hydroelectric generator installation and wiring

The DUO-Option is normally suitable for use with DC generators requiring diversion type charge control. If the generator includes a
voltage regulator it’s setpoint must be set slightly higher than the 3024’s maximum charge voltage setpoint including the effects of
temperature compensation.

¾ WARNING: The generator DC output must be connected to the battery in accordance with the
generator manufacturers installation and safety instructions. The generator is intentionally omitted in the
preceding drawing so as to not preempt the generator manufacturers installation and safety instructions.
DUO-Option diversion operation and associated dump load must meet the generator manufacturers
diversion charge control requirements. Do not connect the generator to the 3024’s PV inputs.


Diversion power controller indicators

As the Diversion power controller increases or decreases it’s PWM “on time” to adjust how much average current is diverted, the
3024’s auxiliary output LED indicator will vary in brightness in proportion to PWM percent on time. The LED will be brighter when more
current is diverted and will be completely off when no current is being diverted. If an IPN-ProRemote is present in the system it’s
auxiliary output screen in the Top Menu will always show Auxiliary Battery Charge. The auxiliary battery voltage displayed in this screen
will be the average voltage applied to the dump load and will vary with PWM percent on time. If actual battery voltage was 14.4V and
the Auxiliary Battery Charge screen shows 7.2V, then Diversion PWM duty cycle (% on time) = 7.2V

÷ 14.4V = 50%.


One year limited warranty

Blue Sky Energy, Inc. (hereinafter BSE), hereby warrants to the original consumer purchaser, that the product or any part thereof will
be free from defects due to defective workmanship or materials for a period of one (1) year subject to the conditions set fourth below. If
within the coverage of this limited warranty, BSE will repair or replace the product at BSE’s discretion. The original consumer purchaser
is responsible for all transportation costs and insurance related to returning the product to BSE. BSE will cover standard ground
transportation costs and insurance to return the product to the original consumer within the continental US.

1. This limited warranty is extended to the original consumer purchaser of the product, and is not extended to any other party.

2. The limited warranty period commences on the date the product is sold to original consumer purchaser.

3. This limited warranty does not apply to any product or part thereof damaged by; a) alteration or disassembly, b) repair or service

not rendered by a BSE authorized repair facility, c) accident or abuse, d) corrosion, e) lightning or other act of God, or f) operation
or installation contrary to instructions pertaining to the product.

4. BSE’s liability for any defective product or any part thereof shall be limited to the repair or replacement of the product, at BSE’s

discretion. BSE will not be liable for any loss or damage to person or property, or any other damages, whether incidental,
consequential or otherwise, caused by any defect in the product or any part thereof. Some states do not allow exclusions or
limitations of incidental or consequential damages, so the above limitation may not apply to you.

5. Any implied warranty for merchantability or fitness for a particular purpose is limited in duration to the length of this warranty. Some

states do not allow exclusions or limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

6. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

7. To obtain warranty repairs, contact BSE at 800-493-7877 or 760-597-1642 to obtain a Returned Goods Authorization (RGA)

number. Mark the outside of the package with the RGA number and return the product, postage prepaid and insured to the address
below. A copy of the purchase receipt identifying original consumer purchaser and date purchased must accompany the product to
obtain warranty repairs.



Blue Sky Energy, Inc.

2598 Fortune Way, Suite K

Vista, CA 92081 USA

800-493-7877

760-597-1642 Fax 760-597-1731

www.blueskyenergyinc.com

430-0027 B

Advertising