Blue Sky Solar Boost 2000 User Manual

Page 9

Advertising
background image

Installation and Operation Manual

8

Factory default setup criteria:

• Liquid electrolyte lead-acid battery

• Standalone operation (i.e. no optional 6210 controller)

• No temperature compensation (i.e. no optional SensorLug battery temperature sensor)

• Difference between PV open circuit voltage and maximum power voltage is 4.4V (V

OC

-V

MP

= 4.4V)

FACTORY DEFAULT SETUP

SWITCH

1

SWITCH

2

SWITCH

3

SWITCH

4

SWITCH

5

SWITCH

6

SWITCH

7

SWITCH

8

OFF

ON

OFF

ON

ON

ON

OFF

ON

BATTERY VOLTAGE

SETPOINT

DIFFERENCE BETWEEN PV

V

OC

- V

MP

14.0 V

4.4 V

TABLE 2

OPERATING MODE

Solar Boost 2000 will operate in one of three modes as shown below. Use the standalone mode when Solar

Boost 2000 is not used with RV Power Products Battery Manager model 6210 components. Note that switch #8 must
always be on.

SWITCH

1

SWITCH

2

SWITCH

3

SWITCH

4

SWITCH

5

SWITCH

8

OPERATING MODE

OFF

ON

OFF

ON

ON

ON

STANDALONE

(DEFAULT FACTORY

SETUP)

ON

OFF

ON

OFF

ON

ON

6210 CONTROLLER

WITHOUT 6210 AC

CHARGER(S)

ON

OFF

ON

OFF

OFF

ON

6210 CONTROLLER

WITH 6210 AC

CHARGER(S)

MPPT DISABLE

The MPPT function may be disabled if desired. To use Solar Boost 2000 with wind power generators or power

sources other than a PV array, disable peak power tracking. With peak power tracking disabled, Solar Boost 2000 will
operate as a series pass PWM type controller. Even if peak power tracking is disabled, PV array current will be less
than output charge current when battery voltage is at the desired setpoint due to the nature of Solar Boost 2000’s
power conversion technology.

SWITCH

6

MAXIMUM POWER POINT TRACKING

ON

ENABLED

OFF

DISABLED

Advertising