INSTALLATION INSTRUCTIONS

California Faucets recommends this product be installed by licensed contractor(s)


THROAT/GRID HEIGHT ADJUSTMENT

(see figure 1)


1.
To obtain proper grid height, rotate THROAT [8] to

raise or lower. One (1) complete rotation of
THROAT [8] is equal to 1/8” in vertical adjustment.


2. Proper height should be determined by flooring

contractor.


3. Before the final mortar application it is suggested to

place some pea GRAVEL [9] over WEEP [7] holes
to prevent blockage of the holes.

NOTE: All figures show cast iron no-hub connection

FIGURE 1




GRID INSTALLATION

(see figure 2, 3 & 4)


1. After completion of finished flooring, remove plastic

MUDGUARD [10] by drilling a hole in the center and
pull out.


2. Place decorative GRID [11] onto drain THROAT [8].

3. Find location of the four SETSCREWS [12] and

tighten all screws securely with supplied ALLEN
KEY [13].




SERVICE ACCESS

(see figure 3 & 4)

FIGURE 2


1. Find location of the four SETSCREWS [12] and

loosen screws with supplied ALLEN KEY [13] by
turning counter clockwise and remove GRID [11].


2. These installation instructions and ALLEN KEY [13]

should be stored in a secure place for future
reference.

FIGURE 4

FIGURE 3