INSTALLATION
INSTRUCTIONS

WALL DIVERTER VALVE

IMPORTANT

All

products are engineered to provide quality performance provided

they are installed and operated properly. To fully enjoy the comfort, safety, and reliability of your

new Wall Diverter Valve, please follow the instructions below.

R

Tel: 714-891-7797
Fax: 714-891-2478
Toll Free: 800-822-8855

www.calfaucets.com

Pg 1

WDV-R_ii_130920

WDV-R & WDV-NS-R

Valve

Body

Detent Disk

Cartridge

3-Way Stop Ring

Nut

Broach

All Thread

Outlet:
Port #2

Oulet:
Port #1

Outlet:
Port #3

Intlet Port

Wall Diverter Installation

-Diverter valve has the capability for 3 port / 5 mode or 2 port / 3 mode operation.
-Inlet is located at the back and bottom of the valve with an arrow for inlet identification.

The outlets are also marked with numbers 1, 2, and 3 respectively.

-For solder connections either directly to the valve, or within 6" of the valve, the CARTRIDGE MUST BE REMOVED
from the body. When soldering do not apply excessive heat directly to the body. Failure to follow these directions

can cause damage to the body, detent disk and or cartridge, and may nullify the warranty.

Connection types: NPT Thread (or) copper sweat "solder"

-Remove all thread, broach, body nut, cartridge and detent disk from valve body.
-Valve comes as standard with default 3 port / 5 mode and can be configured to 2 port / 3 mode.
-Define how many ports and modes are needed for your application and install the valve according

to the inlet / outlets to meet those requirements. (See Fig. 1A & 4)

-Connect the mixed water supply to the diverter valve inlet.
-Connect the outlets to the desired number of applications. (for 3 way) use all 3 outlet ports, and for (2 way) use outlets 1

and 2 to the right, (or) use outlets 1 and 3 to the left. Cap off any unused outlets to avoid potential water leakage
behind the wall. (See Fig. 1 & 4)

-Install adequate bracing support in the wall, and secure the diverter valve to the bracing.
-Remove the 3 way stop ring from the cartridge (See Fig. 1)
-Apply some silicone O-Ring grease to the detent disk and attach it to the bottom of the cartridge aligning the 2 pins

horizontal to the outlet opening of the cartridge. (See Fig. 1B)

Inlet/Outlets: 1/2" NPT Male (or) 1/2" Copper Sweat.

Fig. 1A

-Align the cartridge outlet with the top outlet and insert the cartridge into the body and gently push it all the way in so the detent

disk pins fit into the holes inside the body. When fully inserted the cartridge will be recessed in th top of the valve.

-Install the stop ring according to installation type you have. (2 way stop ring) for 2 way function to the left or right) or 3 way

for all outlets. (See Fig. 2A, 2B & 2C). Parts 2B & 2C are the same, but reversible for 2-Way right or left.

-Install body nut and tighten securely. Then install the broach and all thread (do not overtighten all thread onto body nut).

Fig. 2A

Fig. 2B

Fig. 2C

Included if needed for

2-Way Installation Left

Supplied on unit

3-Way Installation

L

R

Fig. 1B

Cartridge
Outlet

Included if needed for

2-Way Installation Right

California Faucets reserves the right to make modification and specification changes at any time.

Please visit www.calfaucets.com for most current technical data.