Checkline DT-361 User Manual

Page 17

Advertising
background image

17

Emission duration mode

4.4.2

The emission time (ratio) can be set by 0.1º within the range between 0.1º/ 360º and 3.6º/ 360º in
the emission duration mode (DUR). (The emission time setting value shows the strobe emitting
time by angle while a rotating object rotates one revolution (360º).)
While the “UNIT” key is being pressed, the value converted from the emission angle to time can be
checked.
A longer emission time increases the brightness, but a measured object appears to be moving.
Also, a shorter emission time decreases the brightness, but a measured object appears to stand
more still.
Adjust the appropriate emission time according to your application and conditions and use the unit.
Press the MODE key to switch to the phase mode (PHA).

* When the external synchronous signal has not been entered, [ _ _ _ _ _ _ ] and the emission time are

indicated alternately.
When the external synchronous signal has been entered, only the emission time is indicated.

Operation

Display

Increase/decrease the

emission angle

Indicates the time

conversion value

while the key is being

pressed

Emission angle: Decreases

Emission angle: Increases

Indicates the value converted

from the emission angle to time

Indicates the value converted

from the emission angle to time

CCW

CW

Press the key to

switch to the phase

mode

Emission duration mode

Phase mode

Advertising