3

2.0 I

NSTALLATION

2.1 Mounting

Four holes in the base of the AS4000 Series unit provide for secure mounting
in any position. Mounting hardware is not provided with the unit. Refer to
Figure above.

2.2 Interconnections

Two connectors and a fuse are provided at the rear
of the AS4000 Series enclosure. Refer to Figure.

Power Connector: The input power cable
(supplied) is connected to the smaller connector.
Operating power is 115VAC or 230VAC (depending on the modification),
50/60 Hz single phase power with a ground.

Control Cable: A control cable (not supplied) is connected to the larger
connector signal input. Th signal inputs are:

Pin 1: Trigger input—5V, 20mA pulse. Triggers on positive-going edge.

Pin 2: No connection.

Pin 3: Isolated input common for return of Pin 1 and Pin 5.

Pin 4: An external reference input signal voltage, 0 to 6V maximum

or 1.7V minimum to keep lamp flashing.

Pin 5: Lamp failure signal output. This signal confirms the lamp has flashed

flashed as programmed. It is 12V high, with a width approximately
the same as the light pulse (5µS).

Pin 6: External reference return. Chassis ground.

10

Light Output Waveform (based on 12 µF Capacitor)

Spectral Distribution Of Light Pulse (based on 12 µF Capacitor)