Checkline MVC-4000 User Manual

Page 4

Advertising
background image

4

C

CO

ON

NN

NE

EC

CT

TO

OR

R H

HA

AR

RD

DW

WA

AR

RE

E

Part No.

Type

Description

CN104

Power

Connector plug with strain relief, Hirschmann
Type STAK 20 (Included on line cord)

CN103

Power

Connector plug for panel mounting,
Hirschmann Type STASEI 2 (Included with unit)

CN106

Power

Security bracket, Hirschmann Type STASI 3
(Included with unit)

CN105

Control

Connector for cable mounting, Hirschmann
Type Stak 5, 5+ ground signal connector
(for cable) with six crimp contacts

CN102

Control

Connector plug for panel mounting, Hischmann
Type STASEI 5, 5+ ground connector
(Included with unit)

CN100

Control

Security bracket, Hirschmann Type STASI 2
(Included with unit)

2.3 Fuse

A one amp fuse located on the NEMA enclosure provides AC line input
protection.

2.4 Main

Chasis

9

7.0 S

PECIFICATIONS

Optical

Broadband light output

20 millijoules per flash at fiber-optic plane

Flash repetition rate

AS4020 - 20 flashes per second maximum
AS4060 - 60 flashes per second maximum
AS4200 - 200 flashes per second maximum

Input energy to flashlamp

AS4020 - 2.0 joules per flash maximum at 20 Hz
AS4200 - 0.2 joules per flash maximum at 200 Hz

Light output pulse

Less than 25 µS pulse width at all energy settings
at 1/3 of peak energy

Lifetime of flash.lamp

103 flashes while maintaining more than 70%
of initial intensity (estimated)

Electrical

Power Line Requirement

115/230 VAC, 50/60 Hz

Power Consumption

0.5A maximum

Trigger Signal

+5V at 20mA (optically isolated)

Trigger Pulse Width

10 µS (minimum)

Non-Synchronizing Time

200 µS (minimum)

Before Pulse

Turn-On Delay Command

l0 µS (Typical)

To Flash

Environmental

Operating Temperature Range –10 to 110 °F (-23 to +43 °C)

Storage Temperature Range

–40 to +194 °F (–40 to +90 °C)

Operating Altitude Range

Sea Level to 10,000 ft. (3,000 m)

Operating Humidity Range

0 to 90% noncondensing

Shock and Vibration

1.5g, 5 to 200 Hz, per MIL-STD-810C

Enclosure

NEMA Type 13; Confirms to JIC Std, EGP-1-1967
and European Std IEC 529, 1P65; Listed by
Underwriters Laboratories, Inc.

Flash Intensity

Power Indicator
& Mode Switch
(remove cover
for access)

Advertising