Checkline CTM User Manual

Checkline Sensors

Advertising
background image

Table of Contents

1.0 Introduction ......................................................................................................................... 3

1.1

Unpacking

................................................................................................................... 3

1.2

Description

.................................................................................................................. 3

1.3 Important features ....................................................................................................... 4

2.0 Operation

5

2.1

Typical

Operation

........................................................................................................ 5

2.2

Measurement

Practices

.............................................................................................. 6

2.3 Softkey Functions ....................................................................................................... 7

3.0 Confi guration Mode ............................................................................................................ 11

3.1 Accessing the Confi guration Mode ........................................................................... 11

4.0 Changing Sheaves ............................................................................................................. 14

5.0 Achieving Best Accuracy .................................................................................................... 15

5.1

Accuracy

................................................................................................................... 15

5.2 Calibration to Specifi c Wire Type ............................................................................... 15

5.3 Loading Error ............................................................................................................ 15

5.4

Non-repeatability

....................................................................................................... 15

5.5

Non-linearity

.............................................................................................................. 16

5.6

Wire

Characteristics

.................................................................................................. 16

6.0 Troubleshooting .................................................................................................................. 16

1

Most three-point tension meters employ only linear characterization and
have large errors at the midpoints (up to 15%). The CTM uses multi-point
segmenting to correct for non-linearity, reducing it to less than 0.2%.

Creep

Every material including steel exhibits creep under load. It will
neck down over time, quite quickly over the fi rst few seconds
and much slower as time progresses. A wire cable also sees
creep from the wire spacing and wind. This effect is seen as a
display that drifts lower after it has been clamped in line.

Variations

Material that varies in diameter or shape will have different
output at the same tension

Strands

The best cable assembly is one that is perfectly round, as
it will not change contact geometry with the wire twist. The
closer the wire cable cross section appears to be round, the
better the measurement performance will be.

5.5 Non-linearity

5.6 Wire Characteristics

16

Problem

Possible Cause

Solution

Powers on momen-
tarily and turns off

Low battery

Replace with high quality alka-
line batteries

Does not power on

Low battery

Replace with high quality alka-
line batteries

Batteries installed
backwards or no
spring contact

Insure that positive terminals
of both batteries (nub) face in-
ward – towards the black cap.
Check that spring is attached
to the battery cap.

Software reset

Remove battery cap & reinstall
after one minute. Attempt to
turn power on again.

Display contrast too
light

Hold the Right Arrow key down
while pressing the F2 key
several times to increase the
display contrast. If nothing oc-
curs, release both keys. Press
the power button and try again.

Display is
completely dark

Display contrast too
dark

Hold the Arrow key down while
pressing the F1 key several
times to decrease the display
contrast.

Display drifts down-
ward once installed

Wire material is
creeping and inter-
nal friction between
wires is relieved.

This is normal behavior of
wire. Lower display resolution
to mask this effect.

Temperature not
accurate

Instrument changed
temperature envi-
ronments

Allow instrument to remain in
environment until temp stabi-
lizes or enter temp manually

Instrument exposed
to sun

Enter temp manually

6.0 Troubleshooting

Advertising