Checkline TD-1-TE User Manual

Checkline Sensors

Advertising
background image

-1-

1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

2

1.1 Complete Kit

2.0 Overview of Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

3

3.0 Removing/Replacing Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

3

4.0 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

4

4.1 Setting Decimal Point
4.2 Setting the Low Alarm Limit
4.3 Setting the High Alarm Limit
4.4 Enabling & Disabling Electronic Damping

5.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

6

6.0 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

7

6.1 Zero Adjustment
6.2 Gain Adjustment
6.3 Checking the Calibration

7.0 Analog Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

7.1 Changing Analog Output Type
7.2 Zero and Gain Adjustments

8.0 Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

8.1 TD-1-TE Specifications
8.2 Pin Assignments
8.3 On-Line Sensor Specifications

9.0 Warranty

T

ABLE OF

C

ON T EN T S

-16-

8.3 Online Sensor Specifications

Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2)

Calibration:

According to Electromatic factory procedure

Accuracy:

For 10% to 100% of range: ± 1 % full scale

Remainder of
range and other
calibration material

3% full scale or better

Overload protection

100% of range

Measuring principle

Strain gauge bridge

Measuring roller
deflection

0.5 mm, max.

Signal processing

Analog

Output signal:

0 - 1 V DC (standard)

Damping (fg)

Standard: 30 Hz (other values on request)

Temperature
coefficient:

Gain: less than ± 0.01% full scale / °C

Temperature range

10 – 45 °C

Air humidity

85% RH, max.

Power supply

Standard: 12 to 18 VDC (21 mA) (regulated)

Advertising