1. CAM NAME

ON/OFF
ON:

<CAMERA NAME>

ABCDEFGHIJKLM
NOPQRSTUVWYZ
abcdefghijklm
nopqrstuvwyz
‐ 123456789
<‐  ‐>  CLR  POS  END

2.  LENS

MANUAL / DC IRIS

CAMERA NAME:
Insert the Title name  by moving 
the  joystick up/down/left/right.
and pushing the buttom.use the 
bottom arrows if needs to change 
any letter or number on the camera 
name.
Use CLR to erase  
Use POS to change the name 
location on the Screen.

END to exit the camera name 

MANUAL (IRIS MANUAL MENU)
Manual adjustment for the Iris.
Brightness(0~100)

3.  EXPOSURE

AGC

OFF/LOW/MIDDLE/HIGH

SHUTTER

OFF/A.FLK/(1/160)~(1/90000)/x2~X512/AUTO

SENSE‐UP

OFF/AUTO X2~ AUTO X512

INITIAL SET

RESET BACK TO ORIGINAL SETTING

PREVIOUS

Back to Main Menu

Brightness(0 100)
REACTION SPEED(0~8)
DC IRIS(DC IRIS MENU)
Adjust DC IRIS  brightness and iris response 
speed.
BRIGHTNESS(0~100)
REACTION(0~8)
PREVIOUS

AGC:
Automatic Gain Control can be set to LOW, MEDIUM, 
HIGH or OFF. In a dark environment, when AGC is set 
to High, the image becomes brighter. The setting here 

is related to the setting in Day & Night mode

.

SHUTTER:
Electronic Shutter allows the shutter speed to be 
adjusted from X256 to 1/90,000, including a choice for 
A.flicker mode. In FLK mode, shutter automatically 
asjusts to avoid image flicker when there is a 
discrepancy between current and frequency. (If 
MANUAL mode is selected in Lens, this will be AUTO.)

SENSE‐UP:
Sense Up can be set to X2 to X512 (X8 is default) or 
turned OFF. When it is on, the camera controls
sensitivity as it automatically detects the light level in 
dark environments and maintains a clear picture
INITIAL SET:
Reset to factory default settings. 