Cisco 3745 User Manual

Page 14

Advertising
background image

14

Warning

This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than:
20A, 60VDC.
Statement 1005

Warning

Use copper conductors only. Statement 1025

DC Wiring Requirements

A Cisco 3745 router with a DC-input power supply requires copper wire for the power connections. Table 2 summarizes the
wiring requirements.

Wiring Procedure for DC Input

To connect the router to a DC power source, perform the following steps:

Step 1

Remove power from the DC circuit. To ensure that power is removed from the DC circuit, locate the circuit breaker for
the DC circuit, switch the circuit breaker to the OFF position, and tape the circuit-breaker switch in the OFF position.

Warning

Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003

Tip

Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.

Step 2

Strip the wires to the appropriate length for the terminals. The strip length is 1/8 to 3/16 inch (3 to 5 mm) for Molex
number 19073-0009 terminals and for AMP/Tyco number 52961 terminals.

Table 2

DC Wiring Requirements for Cisco 3745 Routers

Installed Power Supply

DC Input

DC Input Wire
Size

Safety Ground
Wire Size

Wire Terminal (Lug)

Overcurrent
Protection

Nominal 24/48 VDC

1

Identified by the following printed
label:

1. The input voltage tolerance limits for nominal 24/48 V power supplies are 18 and 72 VDC.

24 - 36 V, 15 A AWG 12

(3.0 mm

2

)

AWG 12
(3.0 mm

2

),

minimum

Amp/Tyco No.
52961 or equivalent

20 A
maximum

36 - 60 V, 7 A

AWG 12 or 14
(3.0 or 2.0 mm

2

)

AWG 12
(3.0 mm

2

),

minimum

For AWG 12:
Amp/Tyco No.
52961 or equivalent

For AWG 14: Molex
No. 19099-0017 or
equivalent

20 A
maximum

Nominal 48 VDC

2

Identified by the following printed
label:

2. The input voltage tolerance limits for nominal 48 V power supplies are 38 and 72 VDC.

48 - 60 V, 10 A AWG 14 or 16

(2.0 or 1.2 mm

2

)

AWG 14
(2.0 mm

2

),

minimum

For AWG 14 or 16:
Molex No.
19099-0017 or
equivalent

20 A
maximum

100-240V 50/60Hz 10A

OR Input +/- 24-36 V 15 A
36-60 V 7 A

!

CISCO 3745

~

100-240V 50/60Hz, 10A
OR 48-60V , 10A

!

CISCO 3745

~

Advertising