Maximum ratings, Operating range, Electrical characteristics – Cypress CY7C145 User Manual

Page 4

Advertising
background image

CY7C145, CY7C144

Document #: 38-06034 Rev. *D

Page 4 of 21

Maximum Ratings

Exceeding maximum ratings may impair the useful life of the

device. These user guidelines are not tested.

[5]

Storage Temperature

..................................... −65°C to +150°C

Ambient Temperature with

Power Applied

.................................................. −55°C to +125°C

Supply Voltage to Ground Potential

.................−0.5V to +7.0V

DC Voltage Applied to Outputs

in High Z State

.....................................................−0.5V to +7.0V

DC Input Voltage

[6]

..............................................−0.5V to +7.0V

Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage........................................... >2001V

(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA

Operating Range

Range

Ambient

Temperature

V

CC

Commercial

0

°

C to +70

°

C 5V

± 10%

Industrial

−40

°

C to +85

°

C 5V

± 10%

Electrical Characteristics

Over the Operating Range

Parameter

Description

Test Conditions

7C144-15

7C145-15

7C144-25

7C145-25

Unit

Min

Max

Min

Max

V

OH

Output HIGH Voltage

V

CC

= Min., I

OH

=

−4.0 mA

2.4

2.4

V

V

OL

Output LOW Voltage

V

CC

= Min., I

OL

= 4.0 mA

0.4

0.4

V

V

IH

Input HIGH Voltage

2.2

2.2

V

V

IL

Input LOW Voltage

0.8

0.8

V

I

IX

Input Leakage Current

GND < V

I

< V

CC

−10

+10

−10

+10

μA

I

OZ

Output Leakage Current

Outputs Disabled, GND < V

O

< V

CC

−10

+10

−10

+10

μA

I

CC

Operating Current

V

CC

= Max., I

OUT

= 0 mA

Outputs Disabled

Commercial

220

180

mA

Industrial

190

I

SB1

Standby Current

(Both Ports TTL Levels)

CE

L

and CE

R

> V

IH

,

f = f

MAX

[7]

Commercial

60

40

mA

Industrial

50

I

SB2

Standby Current

(One Port TTL Level)

CE

L

or CE

R

> V

IH

,

f = f

MAX

[7]

Commercial

130

110

mA

Industrial

120

I

SB3

Standby Current

(Both Ports CMOS Levels)

Both Ports

CE and CE

R

> V

CC

– 0.2V,

V

IN

> V

CC

– 0.2V

or V

IN

< 0.2V, f = 0

[7]

Commercial

15

15

mA

Industrial

30

I

SB4

Standby Current

(One Port CMOS Level)

One Port

CE

L

or CE

R

> V

CC

– 0.2V,

V

IN

> V

CC

– 0.2V or

V

IN

< 0.2V, Active

Port Outputs, f = f

MAX

[7]

Commercial

125

100

mA

Industrial

115

Notes

5. The Voltage on any input or I/O pin cannot exceed the power pin during power-up.
6. Pulse width < 20 ns.
7. f

MAX

= 1/t

RC

= All inputs cycling at f = 1/t

RC

(except output enable). f = 0 means no address or control lines change. This applies only to inputs at CMOS level standby

I

SB3

.

[+] Feedback

Advertising
This manual is related to the following products: