FIG. 6 VERTICAL AND HORIZONTAL ORIENTATION

Step 2.

When installing firmly push the mounting feet until you hear a
snapping sound. The snap means they are mounted correctly.

Step 3.

After installation give each mounting foot a little tug to make
sure they are seated correctly.

NOTE:

There are several horizontal and vertical mounting
options. It is highly recommended that at least two
mounting feet be used per enclosure.

Step 4.

To mount the enclosure onto a DIN rail. Place the mounting
feet on the DIN Rail and firmly press down until the mounting
feet snap onto the rail.

Step 5.

To remove the mounting feet use a finger on the clip and gen-
tly pull up on the tab.

NOTE:

For Remote Display installation please see Chapter 3,
Installation, of the HI 4050 User’s Guide.

LOAD POINT INSTALLATION

FIG. 7 REAR PANEL

FIG. 8

C2

®

Load Point Connection

Cable color code for C2 Load Points (left to right facing the rear panel):

Shield

Ground Wire

C2-

Violet

C2+

Grey

EXC-

Black

SEN-

Brown

SIG-

White

SIG+

Green

SEN+

Blue

EXC+ Red

Step 1.

Remove the factory installed jumpers from the terminal block
if you are connecting an 8 wire cable from the junction box.
(See Fig. 8)

Step 2.

Connect the cable (Recommended load cell cable: Hardy
Instruments Part # 6020-0001) wires to the Weigh Scale Input-
terminal block according to the cable color chart.

Step 3.

Plug the terminal block into the Weigh Scale Input connector
on the rear panel.

Step 4.

For more information concerning C2 Load Point connection,
consult Chapter 3, Installation, of the HI 4050 User Guide.

Non-C2 Load Point Connection

NOTE:

Cable Color Codes vary between vendors, check with your
supplier for the Color Code for your Non-C2 load point. Do
not connect wires to the -C2 and +C2.

Step 1.

Remove the factory installed jumpers from the terminal block
if you have a 6-wire load cell cable that includes sense wires
from the load cell or junction box.

Step 2.

Connect the cable (Recommended load cell cable: Hardy
Instruments Part # 6020-0001) wires to the Weigh Scale Input
terminal block according to the manufacturer’s specification.

Step 3.

Plug the terminal block into the Weigh Scale Input connector
on the rear panel.

Advertising