Load point installation, C2® load point connection, Non-c2 load point connection – Hardy HI 4060 Rate Controller User Manual

Page 2: Input power wiring, Ac input power wiring (-ac)

Advertising
background image

Step 5.

To remove the mounting feet use a finger on the clip and gen-
tly pull up on the tab.

NOTE:

For Remote Display installation please see Chapter 3,
Installation, of the HI 4060 User’s Guide.

LOAD POINT INSTALLATION

FIG. 5 REAR PANEL

FIG. 6

C2

®

Load Point Connection

Cable color Code for C2 Load Points (left to right facing the rear panel):

Shield

Ground Wire

C2-

Violet

C2+

Grey

EXC-

Black

SEN-

Brown

SIG-

White

SIG+

Green

SEN+

Blue

EXC+

Red

Step 1.

Remove the factory installed jumpers from the terminal block
if you are connecting an 8 wire cable from the junction box.
(See Fig. 8)

Step 2.

Connect the cable (Recommended load cell cable: Hardy
Instruments Prt. # 6020-0001) wires to the Channel terminal
block according to the cable color chart.

Step 3.

Plug the terminal block into the Channel connector on the rear
panel.

Step 4.

For more information concerning C2 Load Point connection,
consult the HI 4060 User Guide.

Non-C2 Load Point Connection

NOTE:

Cable Color Codes vary between vendors, check with your
supplier for the Color Code for your Non-C2 load point. Do
not connect wires to the -C2 and +C2.

Step 1.

Remove the factory installed jumper from the terminal block if
you have 6 wire load cell cable that includes sense wires from
the load cell or junction box.

Step 2.

Connect the cable (Recommended load cell cable: Hardy
Instruments Prt. # 6020-0001) wires to the Channel 1 terminal
block according to the Non-C2 cable color chart, or per manu-
facturers specification.

Step 3.

Plug the terminal block into the Channel connector on the rear
panel.

INPUT POWER WIRING

WARNING: D

O

NOT

PLUG

THE

POWER

CONNECTOR

INTO

THE

HEADER

WITH

LIVE

POWER

. T

O

DO

SO

WILL

RESULT

IN

PROP

-

ERTY

DAMAGE

AND

/

OR

PERSONAL

INJURY

.

WARNING:

IF

A

LITHIUM

BATTERY

IS

REPLACED

WITH

AN

INCORRECT

TYPE

IT

MAY

CAUSE

AN

EXPLOSION

WHICH

WILL

CAUSE

PROPERTY

DAMAGE

OR

PERSONAL

INJURY

.

AC Input Power Wiring (-AC)

WARNING:

DO

NOT

OPERATE

WITH

INCORRECT

LINE

VOLT

-

AGE

.

TO

DO

SO

WILL

RESULT

IN

PROPERTY

DAMAGE

AND

/

OR

PERSONAL

INJURY

. M

AKE

SURE

THAT

THE

POWER

SOURCE

DOES

NOT

EXCEED

240 VAC.

WARNING: I

F

AN

AUTOMATIC

DISCONNECT

DEVICE

IS

USED

ON

THE

AC

INPUT

WIRES

,

THE

DISCONNECT

MUST

ACT

ON

BOTH

THE

LINE

AND

NEUTRAL

WIRES

IN

A

DOUBLE

POLE

,

DOU

-

BLE

THROW

ARRANGEMENT

I

.

E

. DPDT R

ELAY

. U

SING

OTHER

AUTOMATIC

DISCONNECT

ARRANGEMENTS

MAY

CAUSE

PER

-

SONAL

INJURY

AND

/

OR

PROPERTY

DAMAGE

.

The AC power should be supplied by a “clean” pri-
mary line, directly from the power panel. This line
should not supply any other equipment, including
the feeding unit, and should be supplied with a mini-
mum 10 amp breaker.

AC Power Input (See Fig. 7)

Neu (Low)
Line (HI)
Earth Ground

Step 1.

The HI 4060 is configured with a universal power supply rated
from 110 to 240 VAC.

Step 2.

Make sure the VAC power is shut off before installing the
wires to the connector.

Step 3.

Install a 3-wire, minimum 14 AWG power line to the 3-pin ter-
minal block connector.

Relay Outputs

Analog Inputs

Digital Inputs

Control
Output

Relay Outputs

Analog Inputs

Digital Inputs

Control
Output