Accumulator and Counter (Hidden pushbutton):

Press the Capacity Label / Hidden pushbutton to enter the accumulator / counter
recall mode. The display will show "Accunn" followed by the accumulated weight,
then "Countr" follow by the counter value. The display will continue to repeat this
message until a key is pressed. The accumulator / counter recall mode will
display the accumulator value in the units currently selected in the weigh mode.

The accumulator and counter is incremented once every time a manual or
automatic accumulation occurs. When the weight has been added to the
accumulator and the counter has been incremented, the left most display digit
will momentarily display a "o" to confirm operation. The maximum value that can
be shown for the accumulator and counter is 6 digits or 999999. When the
maximum value is reached, the accumulator or counter will rollover starting at a
zero value.

Press the UNITS pushbutton to exit the accumulator / counter recall mode
without changing their values.

Press the ZERO pushbutton, while in the accumulator / counter recall mode to
clear the accumulator and counter values. The display will show "Clr Ac" and
exit from the recall mode.

Press the PRINT pushbutton, while in accumulator recall mode, to transmit the
accumulator and counter values through the RS232 port or optional
communication port. Label buffer 4 contains the print string formatting for the
accumulated weight and counter value. Refer to your dealer or Instruction
manual for details.

Note: Changing the current display units will clear both the accumulator and
counter values while in the weigh mode. Only Available in non Legal for Trade
applications.