Inovonics EN1236D User Manual

En1236d echostream, Two button three condition pendant transmitter

Advertising
background image

© 2011 Inovonics - www.inovonics.com

EN1236D EchoStream

®

Two Button Three

Condition Pendant Transmitter

Installation Instructions - 05601D

1 Overview

The EN1236D is a dual-condition pendant transmitter. The
EN1236D must be used with an EchoStream EN4000 or EN4200
serial receiver or the EN6040 network coordinator. In addition, the
application controller (e.g. control panel) must be designed to
accept the three conditions.

1.1 Inovonics Wireless Contact Information

If you have any problems with this procedure, contact Inovonics
Wireless technical services:

• E-mail: [email protected]
• Phone: (800) 782-2709

1.2 EN1236D Components

Figure 1 EN1236D components

2 Installation and Startup

2.1 Install/Replace the Battery

1. Pry the housing apart at either end and pull the two halves

apart.

2. If replacing a battery, remove the old battery.
3. Install the new battery.
4. Press the Reset button to initialize the transmitter.

2.2 Select the Frequency Band

EchoStream products are able to use a range of radio frequencies,
and must be configured for your geographic area. To configure the
transmitter:
1. Pry the housing apart at either end and pull the two halves

apart.

2. Place a selection jumper on the appropriate frequency band

selection pins.

• Leave the jumper off the pins to set the frequency range to

902-928 MHz for North America.

• Place the jumper on the bottom pins, marked NZ, to set the

frequency range to 921-928 MHz for New Zealand.

• Place the jumper on the top two pins, marked AU, to set the

frequency range to 915-928 MHz for Australia.

3. Press the Reset button to complete configuration.

Caution: When pressing the Reset button, make sure you don’t
also touch the frequency band selection pins. Touching the
frequency band selection pins while pressing the Reset button can
inadvertently set the pendant to the wrong frequency band.

2.3 Register the EN1236D

The EN1236D must be registered with the system in order to be
monitored and supervised. When supervised, the EN1236D will
send a check-in message to the serial receiver or network
coordinator.
Pendants using the 868MHz frequency range for Europe will send a
check-in message every 12 minutes; all other transmitters will send
a check-in message every three minutes.
Each pendant has a unique factory-programmed identification
number. Refer to the control panel’s installation instructions for
details on registering a transmitter.
1. When prompted by the receiver to reset transmitter, press the

Reset button.

2. Replace the cover.

3 Operation

Caution: The EchoStream system should be tested regularly to
ensure operation. To test the system, activate each of the EN1236D
conditions and ensure an appropriate response.

3.1 Activating EN1236D Conditions

The EN1236D can send three different conditions. To send the first
condition, press and hold the left pendant button for one second; to
send the second condition, press and hold the right pendant button
for one second; to send the third condition, press and hold both
buttons simultaneously for one second.
Condition signals are transmitted multiple times and are indicated
by the blinking transmission LED. Inovonics Wireless recommends
you test the transmitter at least once per week.

A Reset button

B Frequency band selection pins

C Battery

B

A

C

Printing Instructions
1. Print Duplex
2. Align and orient back page to match front

page.

3. Cut on dashed line
4. Fold cutsheet in half along the 8.5" axis.

Advertising