Inovonics FA116 User Manual

Page 5

Advertising
background image

© 1997 INOVONICS Corporation

3

LIT-FA116-USER

01860

Programming FA416 and FA464 Receivers



Press

ENTER to review or to modify receiver settings.

Press

Е

Е

Е

Е to go to Output Setup menu or Ж

Ж

Ж

Ж for Review Points.

System ID is encoded in all data transmissions to identify transmitters
to their respective receivers. Enter a code from 000 to 255.

Should the receiver monitor transmitters for inactivity?

Arrow keys toggle between YES and NO.


How long should the receiver wait for a supervisory signal to declare
points inactive?

Enter value from 1 to 99. Arrow keys toggle between MIN and HRS.

To change dealer access code enter number from 0000 to 9999.
(3446 is default.) Note: Default access code may be reset ONLY by
restoring receiver to factory defaults. See below.

Should the receiver look for transmitter data for Vision Plus systems?
Arrow keys toggle between YES and NO.

Reminder: Press ENTER to advance to next menu option. ENTER accepts data in display and proceeds.

What is "Vision Plus Compatibility"?

Vision Plus Compatibility permits transmitters programmed by a the Vision Plus panel to be monitored by an

FA416 or an FA464 receiver AS LONG AS BOTH SYSTEMS HAVE THE SAME SYSTEM ID.Transmitters
monitored by FA receivers need not be programmed by the receiver. Once the receiver hears a Vision Plus-
programmed transmitter, the receiver will consider it one of its own. (Note: any transmitters programmed by
an FA416 receiver will NOT be received by a Vision Plus .)


Initializing FA416 or FA464 receivers: The following sequence will restore the receiver to factory default
settings: (ADV, RESET and DEL Buttons are located on the receiver.)

1. Press and Hold ADV.
2. Press and release RESET.
3. Release

ADV.

4. Immediately, while the Decode and Valid LEDs are off, press and hold DEL

for 6 to 7 seconds.

5. The receiver will flash the TX PRGM LED, indicating restoral complete.

Refer to appropriate appendices for factory default settings.

SYSTEM ID: 123

ACCESS CODE

3446

VISION COMPATIBLE

Å NO Æ

MAX TX INACTIVE

TIME: 4 Å HRS Æ

SUPERVISE POINTS

Å YES Æ

Press ENTER for

Å RCVR SETUP Æ

Receiver

Setup

Advertising