KEYENCE FS-N15CP User Manual

Fs-n15cn/fs-n15cp, Fs-n10 series water-proof type, Precautions for use

Advertising
background image

FS-N10 Series Water-proof Type

FS-N15CN/FS-N15CP

Precautions for Use

The Water resistant type FS-N15C… and the FS-N11C… (FS-N10 Series standard 1 output
M8 connector main unit) differ in the following aspects.
• Protective structure IP66 (IP65 when the Small-diameter fiber unit is used)

• There is no expansion connection, expansion unit connection and interference

prevention function is not supported

• Interference prevention (

), common key operation function (

) is not operational

• External appearance/dimensions and weight

• Main unit/ cover material

• There are two types of adapter for connecting a Fiber Unit (thin fiber unit) with a fiber

cable with a diameter of ø1 or ø1.3, one of each type is included.

When installing the Small-diameter fiber unit, always use the water-resistant adapter
included with the FS-N15C….
If the standard adapter included with the Fiber unit instead of the water-proof adapter
included with the FS-N15C… is used, the protective structure IP65 cannot be met.

* For selection of a fiber unit

• The use of a fiber unit which specifies its IP is recommended.

• In the case of a fiber unit covered with fluorine resin, please make sure that water

does not come into the gap between fibers (black) and the fluorine resin.

*1 Use a cable of 30 m or less.

*2 When the Power Mode is set to HIGH SPEED, power consumption of 100 mW (4.0 mA) will be added.

*3 About the protective structure when a small-diameter fiber unit (the diameter of the cable is ø1.3 or ø1.0) is used.

IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/

93/43/63/63T etc.) is used.

When any small-diameter fiber units except for the above are used, IP65 is applied.

*4 In any of the following cases, the protective structure IP66/IP65 cannot be satisfied.

• When the Fiber Unit and KEYENCE’s M8 connector cable are not connected (Recommended conditions to tighten

up the M8 connector: Tighten it by hand first. Then retighten it as much as 1/16-1/8 of a rotation with pliers.)

• When the dust cover of the Sensor Amplifier is open

• When there is debris in the dust cover

• When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit.

For precautions concerning safe use, as well as regulations and standards, refer
to the “FS-N10 Series Instruction Manual”.

Difference with the Standard Type

Installing the Fiber Unit

Cable Diameter

Adapter

Shape

ø1.3

Water-proof Adapter A

(OP-87379)

ø1.0

Water-proof Adapter B

(OP-87380)

Tip: Black

Tip: Gray

Specifications

Type

1 output type

Cable/M8 connector

M8 connector

*1

Model

NPN

FS-N15CN

PNP

FS-N15CP

Control output

1 output

External input

1 input

Light source LED

Red 4-element LED (wavelength 630 nm)

Response time

50 μs (HIGH SPEED)/250 μs(FINE)/500 μs(TURBO)/ 1 ms (SUPER)

/4 ms (ULTRA)/16 ms (MEGA)

Output toggle

Light-ON/Dark-ON toggle

Timer function

Timer OFF/OFF delay/ON delay/One-shot

Control
output

NPN output

NPN open collector 24 V or less; maximum 100 mA or less,

residual voltage 1 V or less

PNP output

PNP open collector 24 V or less; maximum 100 mA or less,

residual voltage 1 V or less

External input

Input time 2 ms (ON)/20 ms (OFF) or more,

when selecting External calibration 25 ms (ON/OFF) or more

Expansion units/

Number of interference prevention units

0 units (expansion not possible)/0 units (connection not possible)

Protection circuit

Protection against reverse power connection, Output overcurrent, and Output surge

Rating

Power voltage

12 to 24 V DC ± 10% ripple (P-P) 10% or less

NPN

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)

*2

Econ on (ALL): 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)

*2

Eco full: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

PNP

Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)

*2

Eco on (ALL): 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)

*2

Eco full: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)

Environmental
resistance

Operating ambient

luminance

Incandescent lamp: 20,000 lx or less; sunlight: 30,000 or less

Operating ambient

temperature

-20°C to +55°C (no freezing)

Operating ambient

humidity

35 to 85%RH (no condensation)

Vibration resistance

10 to 55 Hz compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axis

Shock resistance

500 m/s

2

, 3 times for each of X, Y, Z axis

Protective structure

IP66

*3

*4

Material

Case

Main unit: glass-reinforced PBT; Cover: Sulfonic resin

Adapter

Glass-reinforced PBT

Case Dimensions

H 31.0 mm × W 13.0 mm × L 94.0 mm

Weight

App. 30g

96M11796

1081-1

Advertising
This manual is related to the following products: