KEYENCE LV-S63 User Manual

KEYENCE Sensors

Advertising
background image

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.

11571E 1120-1 96M11571
Printed in Japan

Make sure to read this section before

performing detection of transparent objects.

For the LV-N10 Series, the recommended settings for the optimal detection of
transparent targets (zero datum recipe) have been set in advance.

„

How to read out the zero datum recipe

1

When there is no workpiece (transparent) press the [SET] and
[PRESET] button simultaneously for 3 seconds.
“T5V” will display blinking.

2

Press the

button to display “.Q#F”, then press the [MODE]

button.

3

Press the

button and select “TFV/”, then press the [MODE]

button.
If the settings are read out “.Q#&QM” is displayed and the present light
intensity displays.

„

How to calibrate when using the zero datum recipe

If the [SET] button is pressed, the present value -5% will be set as the setting
value. (Percent calibration)

Recommended settings when using zero datum calibration

When performing detection of a transparent object, set the zero datum setting
to Hi (high-accuracy) in the special mode settings before performing zero
datum calibration.

„

How to set up special modes

1

Press and hold the [MODE] button,

and [SET] button at the same

time for at least 3 seconds.

2

Press the [MODE] button four times.

3

Use

to select “

” and press the [MODE] button to complete

the settings.

After completing the special mode settings, perform zero datum calibration
with the light entering the sensor (without a workpiece (transparent object)).

„

Setting zero datum

1

Without a workpiece (transparent object) in place, quickly press the
[SET] button once.

2

In this state, press and hold the [SET] button for at least three
seconds, and release when the display flashes.

3

The settings are complete when “0” appears on the red digital
display.

* To increase the distance, set the response time as slow as possible.

Target model: LV-S62/S63

When the sensor amplifier is the LV-N10 Series

When the sensor amplifier is the LV-S Series

[MODE] button

[SET] button

[PRESET] button

Set button

Mode button

Concerning installation of the sensor head

LV-S62/S63

Place the reflector (reflecting board) as

close to the sensor as possible to

achieve more stable detection.*

Reflector (reflecting board)

The position of the mounting holes (vertical or

horizontal) do not affect detection, but it

should not be tilted in comparison to the

sensor head. The received light intensity will

become extremely small.

96M11571

Advertising
This manual is related to the following products: