KEYENCE OP-84351 User Manual

Instruction manual, Lv-s62 dedicated mounting bracket

Advertising
background image

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.

11554E 1120-1 96M11554
Printed in Japan

LV-S62 Dedicated Mounting Bracket

OP-84350/OP-84349/
OP-84351

Instruction Manual

Read this manual before using the product in order to achieve maximum
performance.
Keep this manual in a safe place after reading it so that it can be used at any time.

„

Symbols

The following symbols alert you to important messages. Be sure to read these
messages carefully.

„

L-mounting bracket (OP-84350)

Mounting bracket ×1 / Plate nut × 1 / M3 ×

7.3 screw × 1

1

Insert the enclosed plate screw into
the mounting slot on the back of the
head.

2

Align the protrusion with the hole on
the top of bracket, and attach with the
enclosed mounting screws.

„

Back surface mounting bracket (OP-84349)

Mounting bracket ×1 / M3 ×

18 screw × 2

1

Attach as shown on the right.

2

Adjust the beam axis.

(1) The beam axis angle can be

adjusted sideways by loosening
the screws (a) to (c) and moving
the bracket left and right. Always
tighten the (b) screw first.

(2) The beam axis can be adjusted

in the downward direction by
tightening the screw shown with
the arrow, and can be adjusted
in the upward direction by
loosening the same screw.

„

Horizontal mounting bracket (OP-84351)

Mounting bracket ×1 / M3 ×

18 screw × 2

1

Attach as shown on the
right.

2

Adjust the beam axis.
The beam axis can be
adjusted in the upward
direction by tightening the
screw shown with the arrow,
and can be adjusted in the
downward direction by
loosening the same screw.

It indicates additional information on proper operation.

Always adjust the beam axis in the order of steps (1) and (2).
The screws shown in (1) could be damaged if these steps
are reversed.

Point

The tightening
torque is 0.5N•m
or less.

The tightening torque is
0.5N•m or less.

(a)

(b)

(c)

(a)

(b)

(c)

To move the beam

axis downward

To move the beam

axis upward

Point

When mounting the sensor head in the direction opposite of
that shown above, set the spot selection switch before
mounting.

Spot selection
switch

The tightening torque is 0.5N•m or less.

Point

To move the beam

axis upward

To move the beam

axis downward

96M11554