KEYENCE GV Series User Manual

Series, Instruction manual, Digital cmos laser sensor

Advertising
background image

1

GV-IM-E

Digital CMOS Laser Sensor

GV

Series

Instruction Manual

Read this manual before using the software in order to achieve maximum

performance.

Keep this manual in a safe place after reading it so that it can be used at any time.

The displayed values indicate guidelines for distances and should not
be used in the actual applications for measurement.

* The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in

accordance with the requirements of Laser Notice No.50.

Safety measures for the laser

„

Laser radiation emission indicator

The laser radiation emission indicator lights up after turning on the power and

while the laser beam is being emitted.

„

Laser emission stop input

The laser emission stops when an emission stop (purple line) signal is input (for

20 ms or longer). The emission stops while the signal is input. The laser beam is

emitted a maximum of 20 ms after the signal input is canceled. The control

output functions according to the detection value even while laser emission

stop is input.

„

Laser warning labels

The following diagrams show the type and position of laser warning labels

according to the GV Series.

The IEC warning/explanatory labels are only included with Class 2 laser

products.
When using this product in the countries and/or regions other than U.S., use the

IEC warning/explanatory label in the package of this product.
In this case, it can be affixed on the FDA (CDRH) warning label, which has

already been affixed to this product.

Check if the parts and equipment listed below are included in the package of the

model you purchased before using the unit.

„

Sensor amplifier

„

Sensor head

We have thoroughly inspected the package contents before shipment.

However, in the event of defective, broken or missing items, please contact your

nearest KEYENCE office.

Safety Precautions

WARNING

This product is only intended to detect object(s). Do not use this

product for the purpose to protect a human body or part of a

human body.

This product is not intended for use as an explosion-proof

product. Do not use this product in a hazardous location and/or

potentially explosive atmosphere.

Safety Precautions on Laser Products

WARNING

This product employs a semiconductor laser for its light source.

Use of controls or adjustments or performance of procedures other

than those specified herein may result in hazardous radiation

exposure.

Follow the instructions mentioned in this manual. Otherwise, injury

to the human body (eyes and skin) may result.

Do not disassemble this product. Laser emission from this product

is not automatically stopped when it is disassembled.

Precautions on class /2 laser products

Do not stare into the beam.

Do not direct the beam at other people or into areas
where other people unconnected with the laser work
might be present.

Be careful of the path of the laser beam.
If there is a danger that the operator may be exposed
to the laser beam reflected by specular or diffuse
reflection, block the beam by installing an enclosure
with the appropriate reflectance.

Install the products so that the path of the laser beam
is not as the same height as that of human eye.

Precaution on class 1 laser products

Do not stare into the beam.

Item

Description

Model

GV-H45, GV-H130,

GV-H450, GV-H1000

GV-H45L, GV-H130L,

GV-H450L, GV-H1000L

Wavelength

655nm

FDA (CDRH)
Part 1040.10

Laser Class

Class Laser Product

Class 1 Laser Product*

Output

560

μW

220

μW

IEC 60825-1

Laser Class

Class 2 Laser Product

Class 1 Laser Product

Output

560

μW

220

μW

Note

OUT

LASER

1

2

CLP

OUT

LASER

TIM

BANK

SET

SEL

MODE

1
2

1

2

1

spot

DATUM

series

Laser radiation emission indicator

Sensor amplifier

Sensor head

Checking the Package Contents

GV-H45(L)/GV-H130(L)

GV-H450(L)/GV-H1000(L)

Aperture label

Aperture label

Laser

transmitter

FDA (CDRH)

warning label (Class )*

Aperture label

Aperture label

Laser

transmitter

FDA (CDRH)

warning label (Class )*

* Not included with GV-H45L/H130L/H450L/H1000L.

z

Aperture label

z

IEC warning/explanatory label (CLASS 2)

z

FDA (CDRH) warning label (CLASS

)

The FDA (CDRH) warning labels are only affixed to Class laser products.

MODE

SEL

SET

LASER

1

2

OUT

1
2

TIM

1spot

CLP

BANK

DATUM

MODE

SEL

SET

LASER

1

2

OUT

1
2

TIM

1spot

CLP

BANK

DATUM

series

series

GV-21/GV-21P (main unit)

GV-22/GV-22P (expansion unit)

Amplifier

x1

Instruction manual x1

Amplifier x1

GV-H45(L)/H130(L)

GV-H450(L)/H1000(L)

Sensor head

x1

Insulating sheet

x1

Mounting bracket

x1

Board nut

x1

M3 x L30 screw

x2

Laser warning sticker* x1

Sensor head

x1

Insulating sheet

X

1

Mounting bracket

x1

Board nut

x1

M4 x L35 screw

x2

Laser warning sticker* x1

* This is not included with GV-H45L/H130L/H450L/H1000L.

96M11664

Advertising